INTERNATIONAL
STANDARD IEC 60092-351
International Standard IEC 60092-351 has been prepared by subcommittee 18A: ... 60092-351 IEC:2004(E). IEC 60092 consists of the following parts under ...
http://webstore.iec.ch/preview/info_iec60092-351{ed3.0}en.pdf
INTERNATIONAL
STANDARD IEC 60092-354
IEC 60092-351, Electrical installations in ships – Part 351: Insulating materials for shipboard and mobile and fixed offshore units power, telecommunication ...
http://webstore.iec.ch/preview/info_iec60092-354{ed2.0}en.pdf
MARINE
CABLE
IEC 60092-351. Lowest Installation Temperature -15˚C. IEC 60092-351. Maximum Short Circuit Conductor Temperature +250˚C. IEC 60092-351. Bend Radius ...
http://tfcable.com/productspecs/PDF/Marine/TypeNKOXS.pdf
MARINE CABLE
IEC 60092-351. Maximum Short Circuit Conductor Temperature +350˚C. IEC 60092-351. Bend Radius. 6 x diameter. PERFORMANCE STANDARDS (in accordance with) ...
http://tfcable.com/productspecs/PDF\9 Offshore-Marine-and-Shipboard-MSB/MSB 6 Marine Power Control Signal Shield FR FX M LSOH 600V 1000V 95C.pdf
IEC 60092-350 EXZHELLENT® - MAR Offshore
Cables
Ethylene Propylene Rubber LSF (EPR), IEC 60092-351. (See Core Identification). 3. Individual Screen: • Copper polyester tape with drain wire. 4. Bedding: ...
http://www.generalcable.com/NR/rdonlyres/59FEA8D9-2716-4443-94C1-60CBF7E4580E/0/9899_S1RFOU_REV.pdf
IEC 60092-350 EXZHELLENT® - MAR Offshore
Cables
Ethylene Propylene Rubber LSF (HF EPR), IEC 60092-351. (See Core Identification). 4. Collective Screen. • Copper polyester tape with drain wire. 5. Bedding: ...
http://www.generalcable.com/NR/rdonlyres/EB7BB8E3-5B75-4D2F-955E-4C44DE354330/0/118119_S4BFOU_REV.pdf
Date
IEC 60092-3, IEC 60332-3-22, IEC 60092-351, IEC 60092-359, IEC 60754-1 and -2, and IEC 61034-1 and -2, IEC. 60092-3 or IEC 60092-376 ...
http://www.drakamog.com/pdf/nek606_certs/ABS_DNK_BFOU_RFOU_250V.pdf
Standards and tests:
IEC 60092-350. Part 350: Shipboard power cables - General construction and test requirements. IEC 60092-351. Part 351: Insulating materials for shipboard ...
http://www.drakamog.com/pdfs/nek606_resources/IEC_standards(3).pdf
Certifikati o
kvaliteti Standards IEC 60092-3 Part 3 Cables
...
IEC 60092-351 Part 351: Insulating materials for shipboard power cables. IEC 60092-353. Part 353: Single and multicore cables with extruded solid insulation ...
http://www.bservisi.hr/cc/certifikati.pdf
LS Offshore & Marine Cable
Low smoke version available. Features. Standards. Features. - IEC 60092-350. - IEC 60092-351. - IEC 60092-354. IEC 60092-359. IEC 60092-375. IEC 60092-376 ...
http://www.lsvinacable.com.vn/Download.aspx/8FA7769AF89745FEA7DBB321BA5C7CBF/1/LS_Offshore-Marine_Cable_05050.pdf
Microsoft PowerPoint - Presentation1
Review of IEC 60092-350 and -353. • New standard for cables for telecommunications and data transfer including radio- frequency. • Merge IEC 60092-351 and - ...
http://info.ogp.org.uk/standards/AustraliaEvent/Presentations/17TC18.pdf
H.V RFOU 3C+3EARTH [P19], [P19/P21]
IEC 60092-351, type HF EPR. - Insulation screen : Semi-conducting compound and Semi-conducting tape. - Metallic screen : Copper(annealed or tinned) wires ...
http://www.nexans.com/eservice/Korea-ko_KR/pdf-family_8524/H_V_RFOU_3C_3EARTH_P19_P19_P21_.pdf
ICEFLEX® IEC SH - Low smoke
60092-351, HF-EPR. 2. Inner Sheath : Flame retardant thermosetting compound. Low halogen Chlorosulphonated Polyethylene rubber as per IEC. 60092-359, SH ...
http://www.nexans.com/eservice/Korea-en/pdf-family_14711/ICEFLEX_IEC_SH_Low_smoke.pdf
Brodski
kabel-bxo-bxzo.eng
cross-sections 35 mm2 and larger-sector -shaped conductor. XLPE, acc. to IEC 60092- 351 polyester foil poliolefine, type SHF 1 acc. to IEC 60092-359 ...
http://www.elka.hr/files/Shipboard cables.PDF
Telecom 3luik
101202
the IEC 60092-351, type XLPE. When fire-resistant cables are requested in accordance with IEC 60331, the copper conductors ...
http://www.tkf.nl/brochures/marine cables.pdf
NW4000 pre_installation Package V1.6.pub
XLPE plastic IEC 60092-351. 3. Screen. - drain wire of tinned copper 1,5mm2 (in all sizes). - aluminium polyester tape, IEC 60092-350 coverage 100% ...
http://www.netwavesystems.com/downloads/products/NW4000 pre_installation Package V1 6.pdf
IEC Catalog
2-07
and low smoke halogen-free. EP meeting. IEC 60092-351. Outer Sheath. Low smoke halogen- free flame retardant polyolefin meeting. IEC 60092-359. Type SHF-2 ...
http://www.1st4cables.com/downloads/BFOU_I_250v.pdf
IEC
Catalog 2-07
Meets IEC 60092-350, IEC 60092-351,. IEC 60092-353 AND IEC 60092-359. Flame retardant: IEC 60332-3 Cat A. Low smoke: IEC 61034-2. Acidity: IEC 60754-2 ...
http://www.1st4cables.com/downloads/RFOU_600_1000v.pdf
International
Electrotechnical Commission Standards
IEC 60092-350. Electrical installations in ships - Part 350: shipboard power cables - general construction and test requirements. IEC 60092-351 ...
http://www.batt.co.uk/upload/files/iec_copy2.pdf
British
Standards German Standards Marine & OGP Cable Standards ...
IEC 60092-351. Electrical installations in ships - Part 351: insulating materials for shipboard and offshore units, power, control, instrumentation, ...
http://www.batt.co.uk/upload/files/marine_copy2.pdf
LEONI SeaLine
the technical requirements of IEC 60092-350,. IEC 60029-351, IEC 60092-352, IEC 60092-353, .... of IEC 60092-351, IEC 60092-359, IEC 60092-376. Marking ...
http://www.leoni.com/uploads/tx_downloadleoni/en_sealine_approvals.pdf
PROTOFLEX
EMV-FC (6kV) - Consero: Prysmian Products
according IEC 60092-351. Ethylene-propylene-rubber (EPR) wall thickness according IEC 60092-354. Core identification. Numerical 1-2-3 imprint on the black ...
http://conseroinc.com/pdfs/prysmian/vfd/protoflex_emv_fc_mv.pdf
SIENOPYR-FR
FM2XCH - Consero: Prysmian Products
according IEC 60092-351. Cross-linked polyethylene (XLPE). With numerals. Within a quad, the twoo opposing cores form a pair. Core identification ...
http://conseroinc.com/pdfs/prysmian/shipboard/fm2xch.pdf
BFOU
(i) S3/S7 250V
meeting IEC 60092-353. Insulation. Fire resistant tape and low smoke halogen-free. EP meeting. IEC 60092-351. Outer Sheath. Low smoke halogen- ...
http://www.amercable.com/doc/catalogs/NEK606/BFOU(i)S3-S7.pdf
GexolŪ OneWorld-HF Flame Retardant Low Smoke Halogen-Free Two Core
...
IEC 60092-351. Color code: White-Black. Conductor. Flexible Class 5. (metric) tinned copper per. IEC 228. Sheath (Optional). A low smoke halogen-free ...
http://www.amercable.com/doc/catalogs/oneworld/37-106-Two-Core.pdf
Standards and tests:
IEC 60092-351. Part 351 : Insulating materials for shipboard power cables. IEC 60092-353. Part 353 : Single and multicore cables with extruded solid ...
http://www.electrix-usa.com/NEW WEBSITE 2007/DRAKA TECH SHEETS/STANDARDS & TESTS.pdf
BFOU
P5/P12
meeting IEC 60092-353. Insulation. Fire resistant tape low smoke halogen-free. EP meeting. IEC 60092-351. Core Identification: 2 Core: White - Black ...
http://www.gexol.com/doc/catalogs/NEK606/BFOU-P5-P12.pdf
0.6/1kV RFOU-EMC(FLEX), BFOU-EMC(FLEX) 3C+3E [MR]
Maximum operating conductor temperature 90°C. •. Standaarden. Internationaal IEC 60092-351;. IEC 60092-353; IEC 60092-359;. IEC 60331; IEC 60332-3 Cat.A; ...
http://www.nexans.nl/eservice/Netherlands-nl_NL/pdf-family_8654/0_6_1kV_RFOU_EMC_FLEX_BFOU_EMC_FLEX_3C_3E_MR_.pdf
250V RFOU(I), RFOU(I/C) 0.5, 0.75SQMMxTR type [S1], [S1/S5],
[MR]
Internationaal IEC 60092-351;. IEC 60092-353; IEC 60092-359;. IEC 60092-375; IEC 60092-376;. IEC 60332-3 Cat.A; IEC 60754-1;. IEC 61034; IEC 61034-2 ...
http://www.nexans.nl/eservice/Netherlands-nl_NL/pdf-product_540141485/250V_RFOU_I_I_C_S2_S2_S6_MR_.pdf
BFOU-HCF(i) 250V Instrumentation cables
6 Feb 2008 ... Draka Norsk Kabel. - HCF protection. IEC 60228 class 2. - Conductor. IEC 60092-351. - Insulation. IEC 60092-359. - Sheath. IEC 60332-1 ...
http://www.draka.no/draka/Countries/Draka_Norway/Languages/Norsk/Navigation/Produkter/Datablader/Petrokjemikabel/BFOU_HCF_i_250V_HF_2006.pdf
BFOU-HCF 0,6/1kV
Standards applied. IEC 60092-353. - Design. Draka Norsk Kabel. - HCF protection. IEC 60228 class 2. - Conductor. IEC 60092-351. - Insulation. IEC 60092-359 ...
http://www.draka.no/draka/Countries/Draka_Norway/Languages/Norsk/Navigation/Produkter/Datablader/Petrokjemikabel/BFOU_HCF_1kv_HF_2006_rev2.pdf
English
template for Management Committees
SC18A is merging IEC 60092-351 and -359 in including Mud resistant material for sheathing. B.4 Ecological environment. TC18 is primarily concerned with the ...
http://www.iecstandards.org/cgi-bin/getsps.pl/18.pdf?file=18.pdf
TI(i) 250V
Crosslinked Polyethylene, IEC 60092-351 (HFXLPE). Pair / Triple /. Quad twisting. Numbered white cores are twisted together and wrapped with polyester tape. ...
http://www.dmecables.com/offshore/Shipline/ShiplineTI(i) 250V.pdf
TXOI 250V
Crosslinked Polyethylene, IEC 60092-351 (HFXLPE). Pair / Triple / Quad twisting. Numbered white cores are twisted in pairs/triples. ...
http://www.dmecables.com/offshore/Shipline/Shipline TXOI 250V.pdf
Cable Systems for Gas Turbines
Insulation resistance (500V DC), IEC 60092-351 ......................................>3670 MΩ/km. Environmental & Mechanical ...
http://www.habia.com/published/2/resources/documents/Gasturbines2.pdf
LEONI Sea
Line® Cables
the technical requirements of IEC 60092-350,. IEC 60029-351, IEC 60092-352, IEC 60092-353, ... of IEC 60092-351, IEC 60092-359, IEC 60092-376. Marking ...
http://www.megat.pl/uploaded/download/1194898792.pdf
RFOU
6/10(12)kV
IEC 60092-354. - Design. IEC 60228 class 2. - Conductor. IEC 60092-351. - Insulation ... EP-rubber, IEC 60092-351 (EPR). Insulation screen semicoductive ...
http://www.megat.pl/uploaded/produkty/pr/pdfy/32.pdf
Marine Cables Medium Voltage Cables es Armoured Medium Voltage
...
IEC 60092-351 (insulation). IEC 60092-359 (sheath). > Flame Retardance. IEC 60332-3-22 (cat A) and IEC 60332-1. > Halogen Free Properties ...
http://www.prysmian.fi/export/sites/prysmian-fiFI/attach/pdf/Marine/MV-FHFX_6_10.pdf
Marine Cables Instrumentation Cables es Armoured Instrumentation
...
Materials. IEC 60228 Class 2 (conductor). IEC 60092-351 (insulation). IEC 60092-359 (sheath). > Flame Retardance. IEC 60332-3-22 (cat A) and IEC 60332-1 ...
http://www.prysmian.fi/export/sites/prysmian-fiFI/attach/pdf/Marine/LJST-HF_E_2008.pdf
0.6/1kV RFOU MULTI CORE [P1], [P1/P8]
60092-351,type HF EPR. - Cabling (with filler). - Bedding : Halogen free compound (inner covering). - Armour : Copper wire braid as per IEC 60092-353 ...
http://www.nexans.jp/eservice/Japan-en/pdf-family_8542/0_6_1kV_RFOU_MULTI_CORE_P1_P1_P8_.pdf
0.6/1KV BU Multi Core [P17]
International IEC 60092-351;. IEC 60092-353; IEC 60092-359;. IEC 60331; IEC 60332-3 Cat.A;. IEC 60754-1; IEC 61034;. IEC 61034-2. National NEK 606; NEK 606 ...
http://www.nexans.jp/eservice/Japan-en/pdf-family_8604/0_6_1KV_BU_Multi_Core_P17_.pdf
Aucun titre de diapositive
IEC 60092-351 type HF EPR. IECA S-68-516 type EPR. 5. Instrumentation cable Screen. 6. Fire retardant Halogen Free Inner Sheath ...
http://ewh.ieee.org/soc/pes/icc/subcommittees/subcom_e/E4/2007/Fall07/02-Lukas-071031-IEEE-ICC Nexans-pres.pdf
Technical Specifications -
7810SB
Wireless RF, ABS Type Approved, CMG-LS, IEEE 45 clause 23, IEC 60092-376 clause 17, 60092-351, 60754-1, 60754-2, 61034, UL1865 FT4 Loading, Limited ...
http://jjbelden.com/pdf/7810SB.pdf
Technical Specifications -
1694SB
60092-376 clause 17, 60092-351, 60754-1, 60754-2, 61034. EU CE Mark (Y/N). Yes. EU RoHS Compliant (Y/N). Yes. EU RoHS Compliance Date (mm/dd/yyyy): ...
http://jjbelden.com/pdf/1694SB.pdf
Gexol® OneWorld-331HF Fire Resistant Low Smoke Halogen-Free ...
IEC 60092-3 and. IEC 60092-351. Sheath (Optional). A low smoke halogen- free flame retardant polyolefin meeting. IEEE 45/1580 Type TPO and IEC 60092-359 ...
http://www.offmarcab.com/doc/catalogs/oneworld/37-107-Shielded-Triads.pdf
Marine Cables 2007
IEC 60092-351 marine cable standard is 90 C. Sheathing Material ..... IEC 60092-376. > Materials. IEC 60228 Class 2 (conductor). IEC 60092-351 (insulation) ...
http://www.prysmian.com/export/sites/prysmian-com/attach/pdf/energy/Catalogo_Marine_FIN.pdf
Gexol® OneWorld-331HF Fire Resistant Low Smoke Halogen-Free Two
...
IEC 60092-3 and. IEC 60092-351. Color code: White-Black. Conductor. Flexible Class 5. (metric) tinned copper per. IEC 228. Sheath (Optional) ...
http://www.amercable.net/doc/catalogs/oneworld/37-107-Two-Core.pdf
lloyds04_00086.pdf
wires to IEC 60228, Class 2. XLPE or HEPR to IEC 60092-351:2000. Halogen free polymer to IEC 60092-359:1998. Zinc coated steel wires to IEC 60092-350 ...
http://www.fulgor.com/dynamic/a_pdfs/lloyds/lloyds04_00086.pdf
LKSM-VFD
IEC 60092-353, design. 1. Conductor. - stranded copper conductor. IEC 60228, class 5. 2. Insulation. - XLPE plastic. IEC 60092-351. 3. Bedding ...
http://www.helkamabica.fi/pdf/LKSM-VFD.pdf
LKSM-FRHF
IEC 60092-353, design. 1. Conductor. - stranded copper conductor. IEC 60228, class 2. 2. Insulation. - Mica tape. - XLPE plastic. EC 60092-351. 3. Bedding ...
http://helkamabica.fi/pdf/LKSMFRHF.pdf
1 2