Real-Time Model
Recommendations
Examples of such equations of state are NX-19 (AGA-3) and the ..... The equations recommended by AGA (NX-19, AGA-8) are fitted directly to ...
http://www.psig.org/papers/2000/0008.pdf
Operating
Instruction Manual
only for AGA NX-19. 127. Base pressure p0 [1,0132 or 1,0133 results in 1,01325] ... 12213-3) is used and „2“ means AGA NX-19 modified is used. ...
http://www.imeteritalia.com/instruction_manual.pdf
Modular Electronic
Volume Corrector serie MEVC
compressibility calculation equations in accordance with ISO 12213-3. AGA-NX19 mod. - AGA-NX19 mod. BRKORR3H. AGA-8 gross method 1 - AGA-8 gross method 2 ...
http://www.imeteritalia.com/iTS-MEVC.pdf
Gas meter
according to EN 12405. Z and Zb. Z/Z. 1(ldeal gas) b. Z/Z const 1 b. SGERG 88. AGA NX 19 or AGA NX 19 mod. AGA 8 G1 or AGA 8 G2 ...
http://www.chunhuigas.com/doc/gas_llj2007.pdf
FLOWCOMPUTERS
Compressibility is calculated with a accordance with SGERG-88, AGA-NX19, .... compressibility of gas is appointive in support method SGERG-88 or AGA NX-19 ...
http://www.plum.pl/en/artykuly/produkty_i_uslugi_gaz_ziemny/download/Technical_information.pdf
AGA Flow Applications Software
The AGA8 method provides extended capa- bilities beyond the temperature, pressure, and composition ranges of NX-19. The AGA Reports utility (see Spec. ...
http://ecommerce.red-man.com/shared_files2/ecom/tech_data/fisher_controls/contents/FAS/nw_lit_99/Spec/fw2.pdf
AGA Flow Applications Software
provides extended capabilities beyond the temperature, pressure, and composition ranges of NX-19. An AGA Reports utility, supplied with the GV101 ...
http://ecommerce.red-man.com/shared_files2/ecom/tech_data/fisher_controls/contents/FAS/Spec/FW2.pdf
GASCalc™ 4.0
Hydrocarbon Gases, AGA GPTC Guide For Gas Transmission and Distribution Piping Systems, AGA NX19 Manual For Determination ...
http://www.b3pe.com/docs/GCHighlights.pdf
Measurement and Automation Products
AGA 3 and AGA 7 orifice and linear meters. •. NX-19 and AGA 8 Compressibility calculations. •. ISO Calculations. •. U.S. or Metric measurement units ...
http://library.abb.com/global/scot/scot267.nsf/veritydisplay/355650ef90d1215585257505005edc2f/$File/2101199.pdf
Ams_overview Rev 3.0
AGA 8. X. X. X. NX-19. X. Redlich-Kwong. X. Natural Gas Heat Content. AGA 5. X. X. X. PRODUCTS SUPPORTED. CALCULATION. Table 1.0 Calculations and Products ...
http://library.abb.com/global/scot/scot267.nsf/veritydisplay/ebd7c69140c57ef8852572dd00714f32/$File/Ams overview Rev 3_0.pdf
HART Interface Module
Software is required to configure the AGA flow calculations. For the 1985 AGA3 calculation, the user can select either the NX-19 or the 1985 version of AGA8 ...
http://www.documentation.emersonprocess.com/groups/public/documents/specification_sheets/d301015x012.pdf
FloBoss 407 flier_4_22_04
versions of AGA-3 and AGA-7, as well as AGA-8 and NX-19, are built in. Likewise, sophisticated PID loop control and logic sequencing control schemes can be ...
http://www.documentation.emersonprocess.com/groups/public/documents/brochures/d350381x012.pdf
ELCOR-2
degree according to norms AGA NX-19, AGA NX-19 mod, AGA 8 or SGERG-88. Mechanical concept of the device is selected to operate as a single or dual-channel. ...
http://www.elgas.cz/editor/image/produkty1_soubory/a_elcor2.pdf
miniElcor
according to standards AGA 8-92DC, AGA NX-19 mod,. AGA 8-G1, AGA 8-G2, SGERG-88 or fixed. Mechanical concept of the device is selected to ...
http://www.elgas.cz/editor/image/produkty1_soubory/l065en_200909_minielcor.pdf
FloWEB
Compressibility calculated according to AGA 8, AGA NX 19, ISO 12213-3 or MGERG. • Calorific value directly from gas chromatograph source or from calculation ...
http://www.accutherm.com.au/brochures/PietroFiorentiniFlowebMeteringSystem_676.pdf
Standard GERG
Virial Equation for Field Use
of the AGA NX-19 method (2). In the case of lean natural gases with calorific values lower ... the AGA NX-19-mod method and measured compressibility factors ...
http://www.gerg.info/publications/tm/tm5_large.pdf
Product
Programme
Compressibility calculation in acc. with AGA 8, AGA NX 19 or SGERG 88 ... Compressibility factor acc. to AGA NX 19,. GERG 88 S, AGA 8 ...
http://www.avknederland.nl/pdfs/BR_gas_programma.pdf
Data Sheet EK87
according to SGERG-88 or AGA-NX-. 19... or as a constant ..... or AGA-NX-19 by using actual gas characteristics measured by a gas chromatograph, alter- ...
http://www.elster-instromet.com/en/downloads/EI_DM_EK_87_DS_UK_01_old.pdf
Data Sheet EK-88/K
accordance with AGA-NX-19. Integrated data logger for long-term storage of actual and standard volume as well as mean pressure and tem- perature values ...
http://www.elster-instromet.com/en/downloads/EI_DM_EK_88K_DS_UK_01_old.pdf
microELCOR-2
compression level according to regulations AGA NX-. 19, AGA NX-19mod, AGA8-G1, AGA8-G2 or. SGERG-88. Configuration of the device allows to measure and ...
http://www.ues.net.in/ues.net.in/datasheets/GWF Volume Corrector microelcor2.pdf
mE2_tecnical dataa_EN
according to standard AGA NX-19 mod. - according to standard SGERG-88. - according to standard AGA8-G1. - according to standard AGA8-G2. INPUTS - OUTPUTS ...
http://www.ues.net.in/ues.net.in/datasheets/GWF Volume Corrector Technical data.pdf
Multi-Run
Gas Flow Computer Software
turbine meter flow measurement with AGA-8 or NX-19 gas density calculations. Meeting the requirements of API 21.1,. Custody Transfer RealFLO provides 35 ...
http://www.sagedesignsinc.com/pdf/RealFLO_Brochure.pdf
VEMM TEC PIZ BOX V2 Electronic Volume Corrector - DMC GAS ...
AGA NX 19 or AGA NX 19 mod. • AGA 8 G1 or G2. • SGERG 88. Communication. The PTZ-BOX V2 can be easily configured using the soft- ware and a PC or notebook. ...
http://www.dmc-gas.com.hk/Catalogue/LPG_Catalogue/LPG_MEASURING/VEMPTZ2.pdf
EK230 EN03 data sheet, 12.07.2007
to various methods of calculation (S-GERG 88, AGA NX-19, AGA 8 GC1 and GC2). ... (GC1 and GC2), AGA NX-19 or programmable as a fixed value ...
http://www.elster-instromet.com.cn/downloads/ELS_DM_EK230_DS_UK_03.pdf
Dattus Brochure GA-0013-GB-06.02.qxd
AGA NX-19 formulas: AGA 8. Fixed Z. S GERG 88. AGA NX-19 modified. Specifications. Dattus. Flange. Flow Rate. Pressure Drop. Dynamic. Dynamic ...
http://www.globalgasproducts.com/pdfs/meters/gas-meter-actaris-dattus-fm2.pdf
Physikalisch
Technische Bundesanstalt
Das bisherige AGA-NX-19-mod Rechenverfahren einschließlich der Korrektur ... umwerter prüfen, die nach dem Näherungsverfahren AGA-NX-19-mod arbeiten, ...
http://www.ptb.de/de/org/q/q3/q31/tr/trg9.pdf
Model 999 EN01 data sheet, 01.03.2007
lated to S-GERG-88, AGA NX 19, AGA 8 and nitrogen (100%) or is taken into account as a fixed value. The volume corrector is intrinsically ...
http://www.elster-instromet.dk/downloads/ELS_DM_Model_999_DS_UK_01.pdf
Model 555 EN01 data sheet, 01.03.2007
AGA NX-19, AGA 8 (GC1 or. GC2), nitrogen (100%) or programmable as a fixed value. Possible integration into remote data transfer systems. Alarm state input ...
http://www.compteurs-magnol.fr/downloads/ELS_DM_Model_555_DS_UK_01.pdf
Title: Status of AGA Report No. 3 by E.L. Upp
STATUS OF AGA REPORT ...
A related part of AGA work will be the redefining of the NX-19 (super-compressibility factors) to reflect an Fpv factor of 1.0000 ...
http://www.daniel.com/library/Gas/AppNotes/Standards/Status of AGA Report No. 3 by E.L. Upp 1985 37KB.pdf
(I-1171) Auto
Corrector Data Sheet - Sensus
AGA NX-19 compressibility ratio. Its intrinsically safe design provides total .... Calculated by AGA NX-19 methods. Maximum accuracy is achieved ...
http://na.sensus.com/gas/pdf/I-1171.pdf
7950 Gas Signal Converter
AGA-NX19-mod3h. Base temp value. Base pressure value. "Yes". Edit. NX19 ... AGA-NX19 method. (Selection). Curve fit. Live CO2 value. Live N2 value ...
http://www.ivesequipment.com/customer/iveqco/principals/solartron/manuals/501020_AD.pdf
XARTU-5 Brochure.pub
The XARTU/5 can calculate corrected volume using AGA-3, AGA-5, AGA-7, AGA-8 and NX-19 Reports and is fully compatible with Eagle Research's entire family of ...
http://www.eagleresearchcorp.com/Images/Products/XARTU-5 Brochure.pdf
SCADASense Transmitters and Gas Flow Computers
AGA-8 (1992) and NX-19. Event/Alarm/. History Logs n/a n/a n/a. 35 days hourly history,. 35 days daily history,. 700 events and 300 alarms ...
http://www.controlmicrosystems.com/media/product-literature/scadasense/scadasense-comp-chart/SCADASenseCompChart_V017.pdf
UNITED STATES DEPARTMENT OF THE INTERIOR BUREAU OF LAND MANAGEMENT
...
Supercompressibility shall be determined in accordance with AGA Committee Report. No. 3, 1985 (API 14.3, 1985), AGA-8, or NX-19. Informational Requirements ...
http://www.blm.gov/pgdata/etc/medialib/blm/wy/programs/energy/og/ogdocs.Par.7786.File.dat/04wy-efcntl.pdf
United States Department of the Interior
3, 1985), AGA-8, or. NX-19. Informational Requirements. 4. For each meter, the EFC shall display, at a minimum, the previous day gas volume ...
http://www.blm.gov/pgdata/etc/medialib/blm/co/programs/oil_and_gas.Par.49812.File.dat/efcntlnotice200701a.pdf
795X
Series flow computers
Compressibility derived from AGA 8, NX 19. (Mod and Mod 3H), or SGERG. • Specific gravity derived from gravitometer source or from calculation using base ...
http://www.inenco.hr/pics/solartron_mobrey/sol_mob_8/b1248.pdf
Solartron
Compressibility derived from AGA 8, NX 19 (Mod and. Mod 3H), or SGERG. • Specific gravity derived from gravitometer source or from calculation using base ...
http://kora.rencal.hu/pdf/b1248.pdf
FLOW
COMPUTER SYSTEM ERZ 2000 FLOW COMPUTER SYSTEM ERZ 2000
AGA-NX-19 and AGA-NX-19 mod. - Beattie-Bridgeman (for industrial gases). - van der Waals equation. Calculation is performed simultaneously. The powerful ...
http://www.rmg.com/uploads/myth_download/erz2000_leaflet_en.pdf
GAS
VOLUME CORRECTOR EC 24 GAS VOLUMEE CORRECTTOOR EC 24
sions with AGA-NX 19 or AGA 8 Gross 1/2 are also available). • 4-20 mA current output (transmitter). For designs with a current output board an external ...
http://www.rmg.com/uploads/myth_download/ec24_leaflet_en.pdf
United States
Department of the Interior
3,1985), AGA-8, or NX-19. Informational Requirements. 4. For each meter, the EFC shall display, at a minimum, the previous day gas volume and the ...
http://www.oipa.com/page_images/1189176588.pdf
GLE ESE RCH ORPOR TION
The XARTU/1 can calculate corrected volume using AGA-3, AGA-5, AGA-7, AGA-8 and. NX-19 Reports and is fully compatible with Eagle Research's entire family ...
http://www.hughesmeasurement.com/Eagle/XARTU-1 MVT-Orifice Literature.pdf
AutoPILOT PRO spec
AGA 8 Gross-1992; AGA 8 Detail-1992; AGA 8 Short-1988; NX-19; NX-19 Analysis; GERG. Differential Meters (DP, Orifice). AGA 3/ANSI/API 2530-1992 Method 2; ...
http://www.thermo.com/eThermo/CMA/PDFs/Product/productPDF_51212.pdf
Simplified GERG Virial Equation for Field Use
fied AGA NX-19 is able to predict the compressibility factor of ... For these types of gas, modified AGA NX-19 is unable to predict ...
http://www.onepetro.org/google/Papers/SPE/eJournal_Papers/spe/1991/PE/08/00017767/00017767.pdf?id=00017767&soc=SPE
Accurate Prediction of Compressibility Factors by the GERG Virial
...
For the modified version of the AGA NX-19 method, 1>2 the deviations for the same experimental data may be as great as 1 %. ...
http://www.onepetro.org/google/Papers/SPE/eJournal_Papers/spe/1991/PE/08/00017766/00017766.pdf?id=00017766&soc=SPE
TRENDS OF
DENSITY MEASUREMENT BY INTERNATIONAL TRANSPORT OF ...
widely used methods are AGA NX-19-mod [1], AGA8- ... The AGA NX-19-mod method is described in ..... AGA Nx 19 to the more precise one - SGERG 88) for ...
http://www.imeko2009.it.pt/Papers/FP_562.pdf
Layout
1
AGA 8 Gross-1992; AGA 8 Detail-1992; AGA 8 Short-1988; NX-19; NX-19 Analysis. Differential Meters (DP, Orifice). AGA 3/ANSI/API 2530-1992 Method 2 or ...
http://www.thermo.com.cn/Resources/200802/productPDF_1246.pdf
FV NOS_PDS_Web Rev 001 08_2007.indd
Chapter 11.2.2. Gas Compressibility: PAR Research Project NX-19 (3 component). NX-19 (20 component). AGA-8 1985, AGA-8 (20 component). AGA-8 (3 component) ...
http://www.field-vision.com/products/FV NOS_PDS_Web Rev 001 08_2007.pdf
Flow Computer for Steam, Heat, Gas, Liquids
2 = AGA NX-19 calculation for natural gas. 3 = Three Relays. 4 = Stacked DP option. 5 = Datalogger option (consult factory) ...
http://www.krohne.com/fileadmin/media-lounge/PDF-US/VA11_DS_990046.pdf
Multi-Run
Gas Flow Computer Software
flow measurement with AGA-8 or NX-19 gas density calculations. .... NX-19. Measurement Update. Once per second; up to 10 Gas Flow Runs. AGA 3, 7, V-Cone ...
http://www.nordictron.no/nordictron/docs/RealFLO_Brochure.pdf
Flow Computer.pub
The XARTU/1™ can calculate corrected volume using AGA-3, AGA-8 and NX-19 Reports and is fully compatible with Eagle Research's entire family of products. ...
http://www.precisionpipeline.com/PDF Documents/Eagle/Flow Computer.pdf