BIFURCATION
STENTING
by VHT Chen - Related articles
http://www.sis.org/docs/2006Yearbook_Ch3.pdf
Stentys coronary
bifurcation stent
The Stentys Coronary Bifurcation Stent is made from nitinol, a nick- ... Illustrating the principle of the Stentys bifurcation stent deployment. ...
http://www.stentys.com/pdf/EuroIntervention.pdf
Bifurcation Stenting
Bifurcation stents, coronary bifurcation lesion, coronary disease ... configurations or bifurcation angles, two-stent techniques are critically needed. ...
http://www.touchcardiology.com/files/article_pdfs/Chen.pdf
Evaluation
of the dedicated Frontier coronary bifurcation
stent: A ...
The stent then becomes in phase with the bifurcation by self-rotation and was advanced into the ..... bifurcation stent systems will combine a specific CBL ...
http://www.springerlink.com/index/6365204061172235.pdf
Why should a dedicated bifurcation stent be
preferred for the ...
Nile CroCo drug-eluting bifurcation stent – strut 76 microns ... Dedicated bifurcation stents may improve flow- more laminar, appropriate sheer stress ...
http://www.minvasys.com/_files/medpub/643920090521_1225_room5_ormiston_john.pdf?PHPSESSID=f4e554d1a430572c5d00d548764b0b63
Microsoft
PowerPoint - Bifurcation stent M vs C2
Three stents optimally welded to accommodate multiple bifurcation angles ... Stent &. 2 balloons. Stent &. 2 balloons. MDT Branch Bifurcation Stent Design ...
http://www.summitmd.com/pdf/pdf/090626_aps09_883.pdf
UNSURPASSED
SIDEBRANCHABILITY FOR EFFECTIVE BIFURCATION
STENTING
There are unresolved challenges facing bifurcation stenting. At present, .... R Stent's UnsurPassed sidebRanchability for bifurcAtion stenting ...
http://www.elmed.com.tr/Kardiyoloji/Brosur/R stent.pdf
Bifurcation
stenting; 'Stepwise approach” for Invatec Twinrail
DEB for Bifurcations. 5. Various Techniques for Stenting Bifurcation Lesions. Bifurcation Lesion. Main vessel. Side- branch. Stent+PTCA. Stent+stent ...
http://www.eurocor.de/e5/e23/content710/DiorTCT07.pdf
devices
Bifurcation stenting: current strategies and
new
Figure 7 The Petal (A, B) and Antares (C–E) bifurcation stents both have preformed side apertures with struts that expand into the side branch (SB) to ...
http://heart.bmj.com/content/95/6/495.full.pdf
Bifurcation Stenting: The Next Generation (c) 2006
Windhover ...
about bifurcation stenting so far: that the delivery technology needs to be simpler and ..... [W#200610199] Bifurcation stent companies will probably enjoy ...
http://www.trirememedical.com/documents/Startup-Magazine-Dec-06.pdf
Bifurcation
stenting; 'Stepwise approach” for Invatec Twinrail
DES is more effective in preventing in-stent restenosis. HOWEVER: ... Growing insight in factors influencing in-stent restenosis: ...
http://www.invatec-china.cn/UserFiles/Stella Skylor.pdf
FIRST-IN-MAN IVUS FINDINGS USING THE MEDTRONIC BIFURCATION
STENT ...
17 Apr 2010 ... Background: Bifurcation coronary lesions represent a challenging lesion subset even in the drug-eluting stent era. The Medtronic Bifurcation ...
http://content.onlinejacc.org/cgi/reprint/55/10_MeetingAbstracts/A199.E1873.pdf
Acute
and Long-Term Results of Bifurcation Stenting
(from the ...
successful bifurcation stenting with a low MACE rate is possible in most patients using a ..... drug-eluting stents for bifurcation stenting have had a ...
http://www.coryi.org/cardiology/AcuteandLongTerm2006.pdf
Novel Coronary Stent Platforms
dedicated stents for bifurcation lesions have been de- .... The StentysTM coronary bifurcation stent. The struts can be disconnected using an angioplasty ...
http://synapse.koreamed.org/Synapse/Data/PDFData/0054KCJ/kcj-38-393.pdf
PowerPoint
Presentation
4 Mar 2010 ... Photograph of a fully-deployed Taxus® bifurcation stent .... •A family of dedicated bifurcation stents may be required to manage all lesions ...
http://www.rmsolutions.net/rmfiles/Bifurcation-2010/001008.pdf
Bifurcation Stenting
MADS classification of bifurcation stenting techniques. 1 Stent. After balloon. 2 Stents. 3 Stents. M. Main prox. first. A. Main Accross side first ...
http://www.cardio-sfc.org/groupes/groupes/atherome-coronaire-et-cardiologie-interventionnelle/enseignement/diu-de-cardiologie-interventionnelle/cours-2eme-annee/cours/annees-precedentes/groupes/groupes/atherome-coronaire-et-cardiologie-interventionnelle/enseignement/diu-de-cardiologie-interventionnelle/cours-2eme-annee/cours/annees-precedentes/2eme-annee-programme-des-cours-2008-2009/files/louvard2.pdf
Provisional
bifurcation stenting
Bifurcation lesions were cumbersome for the early stents. .... Provisional bifurcation stenting is an attractive option that ...
http://www.informaworld.com/index/MFMFEQH9NB0DCPE2.pdf
Evaluation of ABS, an everolimus eluting dedicated
bifurcation ...
dedicated bifurcation stent in a porcine coronary stenting model in comparison with. XIENCE VR coronary stent. O. Sorop1, H.M.M. Van Beusekom1, ...
http://europcronline.congrhealth.com/diapos/EuroPCR2009/8137-20090520_1058_room124-125_Sorop_Oana/Sorop_20090520_1058_room124-125.pdf
슬라이드
1
Role of IVUS in bifurcation stenting. Role of IVUS in bifurcation stenting .... and stent apposition. Role of IVUS for LMT bifurcation lesion ...
http://www.e-bifurcation.org/upload/board/Jong-Seon Park.pdf
Two-Stent Techniques for the Treatment of Coronary
Bifurcations ...
by I IAKOVOU - 2005 - Cited by 4
http://www.hellenicjcardiol.com/archive/full_text/2005/3/2005_3_188.pdf
Devax Receives IDE Approval to Commence DIVERGE II
29 May 2009 ... Eluting Bifurcation Stent System (AXXESS System), ... the treatment of bifurcation lesions with the AXXESS stent to standard techniques with ...
http://www.hbmpartners.com/assets/pdf/pressemitteilungen/2009/20090529_Devax_Receives_IDE_Approval.pdf
Paclitaxel-eluted balloon for Provisional Stenting
During ...
Schampaert E, Fort S, Adelman AG, Schwartz L. The V-stent: A novel technique for coronary bifurcation stenting. Cathet Cardiovasc Diagn 1996;39:320–326. ...
https://www.endovascularonlus.org/perfetto/docs/PERFETTO_protocol.pdf
ENDEAVOR III
Specialty designs (e.g. for LM disease). Dedicated Bifurcation Stents .... TriReme Bifurcation Stent. Design Characteristics. Stent Design ...
http://www.citmd.com/CIT/2007/down/2-4.pdf
Bifurcation disease accounts for up to 15% of
all
of bifurcation disease in patients with stent thrombosis .... Multilink Frontier Bifurcation stent consisting of a stainless-steel stent with ...
http://www.trytonmedical.com/documents/PCI for Bifurcation Disease Sept 2007.pdf
Bifurcation lesions: a never-ending challenge
11 Nov 2008 ... but not least 'true' bifurcation stents (Medtronic). These dedi- cated bifurcation stents could be of particular interest in the ...
http://eurheartj.oxfordjournals.org/content/early/2008/11/11/eurheartj.ehn385.full.pdf
Clinical
and Procedural Evaluation of the Nile Croco® Dedicated ...
carried out with the Multi-Link Frontier coronary bifurcation stent .... stent and delivery system for the treatment of bifurcation ...
http://www.minvasive.de/linked/garcia int. card. journ..pdf
Bifurcation
Lesions…no
AXXESS Stent. • The first drug-eluting stent for bifurcation lesions. • Over 400 patients treated to date in clinical studies. ...
http://www.encoreseoul.org/upload/board/Peter.pdf
The Nordic Bifurcation Studies - an update -
Studies an update
bifurcation lesions with sirolimus eluting stents. The simpel strategy used in the main vessel group ... complex bifurcation stenting strategy in selected ...
http://www.bifurc.net/files/medtool/webmedtool/icpstool01/stud0124/pdf00001.pdf?PHPSESSID=86957d665aca3cfe7d5293f52d705ac9
Download the PDF - Bifurcation treatment
considerations
bifurcation. ● Late outcomes at bifurcation were excellent. ● I have discussed the permutations and combinations of how the stents may have inter-related ...
http://www.pcronline.com/diapos/EuroPCR2008/4948-20080515_1800_Room118-119_Ormiston_John/Ormiston-20080515-1800-Room118-119.pdf
Bifurcation lesions are one of the major unsolved
Bifurcation PCI with simultaneous kissing Y or V stenting ... images of (A) a proximal stent segment and (B) bifurcation stent carina. ...
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1860687/pdf/981.pdf
Emerging Stent Technologies: Adding Innovation and
New Science to ...
BRANCH: Bare Metal Bifurcation Stent Clinical Trial in ... Dr. Hermiller: If it's a bifurcation where you think you can get away with 1 stent, I think they ...
http://www.theheart.org/documents/sitestructure/en/content/programs/1014161/transcript.pdf
Microsoft PowerPoint - sat 0350 pm dean high risk Complex PCI
...
Bifurcation stenting associated with high restenosis without kissing technique and no better outcome compared to POBA of branch ...
http://www.acc.org/education/pdfs/ivboard_2008/sat 0350 pm dean high risk Complex PCI Board review 2008.pdf
DOI:
10.1177/0218492309102527 2009;17:79-81 Asian Cardiovasc ...
Self-Expanding Bifurcation Stent for Malignant Esophagotracheobronchial Fistula ... bifurcation stent is necessary. This is the first report ...
http://asianannals.ctsnetjournals.org/cgi/reprint/17/1/79.pdf
Stenting of
Coronary Bifurcation Lesions: Case Series Vladimir
...
by V Kotevski - Related articles
http://www.cmj.hr/2002/43/6/06.pdf
Slide
1
Unique alloys for stents. – Bioabsorbable drug eluting polymer MEMS stents. – Bifurcation stent. – Technology for microstructures on stents ...
http://www.gabio.org/attachments/3/200700211200HSCBD.pdf
AICT -
Programme as at 20100507-working copy (3)
Overview of Recent Clinical Trials: 2-stent vs 1-stent Strategy. 1620 - 1630. Imaging Techniques in Bifurcation Stenting (IVUS, OCT). 1630 - 1640 ...
http://www.aict2010.org/document/AICT_Programme.pdf
ESVB2007
buellesfeld
Axxess Bifurcation Stent (Devax). Axxess Biolimus Eluting Stent. • Stent: Self expanding nickel-titanium. (Nitinol) alloy ...
http://www.esvb.net/pdf/ESVB2007 buellesfeld.pdf
Safety and efficacy of
drug-eluting balloons in percutaneous ...
by JC Fanggiday - 2008 - Cited by 11
http://www.alvek.eu/pdf/DEBIUT_CCI.pdf
Microsoft PowerPoint - ICI Bifurcation dedicated
stents.ppt ...
One stent technic is a simple and effective approach. Bifurcation dedicated stents ... The Mystery of Bifurcation Stenting. 7. 2 stents are inferior to one ...
http://www.congress.co.il/ici2008/images/stories/pdf/hall_a/tuesday_9/s12/0918_Hoffmann_A_Tue.pdf
Live Case #2:
ST, 50 yrs old M
Eluting Stents in Bifurcation Lesions: NORDIC Bifurcation Study .... Complex Lesions: Trifurcation/Bifurcation Stenting. An approach for tri-bifurcation ...
http://www.ccclivecases.org/pdfs/LiveAug.pdf
Stent-assisted
Coil Placement in a Wide-necked Persistent ...
coils in place, bifurcation stent implantation with re- constructive coronary techniques may be helpful, un- til appropriate devices are available. ...
http://www.ajnr.org/cgi/reprint/23/3/437.pdf
No Slide Title
Stenting of Coronary Artery Bifurcation Lesions. The Nordic Bifurcation Stent Technique Study. Pål Gunnes, Matti Niemela, Kari Kervinen, Andrejs Erglis, ...
http://www.clinicaltrialresults.org/Slides/Hermiller_BifurcationTxTrategies.pdf
Summary
bifurcation stenting techniques have been proposed with various levels of ... to define optimal design parameters for a bifurcation stent. ...
http://www.firw.ugent.be/doctoraat/doctoraten/documenten/samenvatting/Mortier_summary.pdf
Nordic-Baltic
Bifurcation Study III A Prospective Randomized
Trial ...
Bifurcation Lesions Undergoing Treatment with a. Single Stent ... bifurcation stenting strategy. • In the simple one-stent technique the ...
http://www.sbhci.org.br/pdf/tct_2009/Niemela_nordic.pdf
main
in-stent restenosis involving
bifurcation Sirolimus eluting ...
by CH Lee - 2004 - Cited by 1
http://publishing.eur.nl/ir/repub/asset/8298/15084563.pdf
The AneuRx stent graft: Four-year results and
worldwide experience ...
by CK Zarins - 2001 - Cited by 192
http://171.65.102.190/zarins_bib/zarins_pdf/2001/stent_zarins_jvs01.pdf
Carat
Tutorial - Angioplasty
Stenting Variations. We will use a complex LAD bifurcation stent procedure to illustrate the. CARAT stent documentation process, specifically a Culotte ...
http://www.approach.org/forms/Carat Tutorial - Angioplasty.pdf
Theoretical
and experimental basis for the development of a ...
mic bifurcation stent made of silicone which incorporates horseshoe-shaped steel struts. A flexible posterior membrane enables dynamic compression during ...
http://erj.ersjournals.com/cgi/reprint/7/11/2038.pdf
COLOMBO
- Microsoft PowerPoint - COLOMBO - ROMA A Colombo 08
Devax: Drug coated bifurcation stenting, Germany 2005. A large randomized trial has been launched in USA. ✓ Bioabsorbable Drug-Eluting stent: The ...
http://www.ssfa.it/allegati/Ottimizz.Sperimentazioni_colombo.pdf
No Slide Title
Bifurcation stents: novel solutions. The Invatec bifurcation stent solution. A. Colombo ... Common alternatives for Bifurcation Lesions (BL) stenting ...
http://www.medicaldobrasil.com.br/site/doc/ID_133_Bifurcated Stent.pdf
1 2
