4Accessories q Technical mPart
3Connectors
NAMUR sensors per DIN 19 234 consist generally of an oscillator, which is damped by the ... Supply voltage UB per DIN 19 234V. Ripple of power supply ...
http://www.cieco.com/Namur.pdf
Q45 series according to DIN 19234 (NAMUR)
according to DIN 19234. (NAMUR). 30 cm. IR light operate cable. Q45-AD9-D. 30 376 17. 30 cm. IR light operate connector Q45-AD9-D-Q. 30 376 27 ...
http://info.bannersalesforce.com/xpedio/groups/public/documents/literature/ed036.pdf
T30 Series NAMUR Fixed-Field Sensors
DIN 19 234 NAMUR, EN 50 014 Part L 1977, EN 50 020 Part 7. ... NOTE: If sensors with output characteristics according to DIN 19 234 (e.g., T30AD9 Series ...
http://info.bannersalesforce.com/xpedio/groups/public/documents/literature/41685.pdf
871C 2-Wire NAMUR
conforms to NAMUR specifications (DIN. 19 234) allowing these sensors to be ... 5-15V DC (8.2V DC nom., Ri = 1kohm, DIN 19 234) ...
http://literature.rockwellautomation.com/idc/groups/literature/documents/ca/871c-ca505_-en-p.pdf
Series 55 incremental hollow shaft encoder / DIN
19234
Series 55 incremental hollow shaft encoder / DIN 19234. 5 5 X X - 0 2 X R - X X X X. Shaft Size. Connection. Resolution - ppr. 10 = 10 mm. 1 = 2m cable ...
http://www.tachopradnice.com.pl/enkodery/pdf/hohner_automation/inkrementalne/seria_55.pdf
Series 14 incremental hollow shaft encoder / DIN
19234
Series 14 incremental hollow shaft encoder / DIN 19234. 1 4 X X - 0 2 X X - X X X X. Shaft Size. Connection. Resolution - ppr. 07 = 1". 02 = 2m cable ...
http://www.tachopradnice.com.pl/enkodery/pdf/hohner_automation/inkrementalne/seria_14.pdf
Inductive Proximity Switch
Sensors according to DIN 19234 do not contain a ... In DIN 19234, standards for safe functioning between sensor and amplifier are fixed. ...
http://sensorik.pulsotronic.de/shop/pdf-all-en/normen/Ind_ Naeherungsschalter.pdf?ld=2394efebd8435502238c11bd8b3f758a
Operating
Instructions Intrinsically Safe Isolation Relay for ...
Intrinsically safe according to NAMUR and DIN 19234. Terminals: 1+, 2+, 3-. Floating voltage: approximately 8 VDC. Short circuit current: approximately 8 mA ...
http://www.koboldusa.com/datasheet/REL-6_datasheet_man.pdf
Standards
Used
DIN 19 234(Namur). German standard defining the electrical interfacing between a 2-wire DC electri- cal position switch and a signal converter. ...
http://www.farnell.com/datasheets/311448.pdf
1 Transformer
Isolated Barriers KFD2-SRA-Ex* Output: Relay Aufbau ...
in accordance with IEC 60947-5-6 (NAMUR, DIN 19234); see system description for electrical data. Coordination of insulation accord. to DIN EN 50178 ...
http://www.farnell.com/datasheets/102378.pdf
General Specifications YOKOGAWA
DIN 19 234 (NAMUR). Power supply. : 230 V AC; 115 V AC; 24 V DC. Relay output. : 1 or 2 potential-free changeover contacts. Switching capacity ...
http://aspzone.us.yokogawa.com/downloads/MI/General Specifications/General Specification/GS+1R1B7-E-H(E3).pdf
Monitoring Relays
Tachometer Type SM 155
Ex. 3, 4 - Electr. trig. with NAMUR/DIN 19234 sensor. The relay is controlled by ... tive sensors (NAMUR/DIN. 19234) (examples 3 and 4). Examples 1 and 3 ...
http://www.gavazzionline.com/pdf/SM155.eng.pdf
AECO CATALOGUE
The NAMUR (DIN 19234) proximity switches are electronic sensors whose absorbed current varies in the presence of metallic objects. ...
http://www.z-trauq.com/sensors/Namur.pdf
Signal Box
827.S
2-core system acc. to DIN 19234 (NAMUR) for switch amplifier in safety ... The proximity switches acc. to DIN 19234 or acc. to NAMUR respectively, ...
http://www.arca.de/download/2/827S-TB-04-07-GB.pdf
EWS-xxxxC-Nxx
to connect pickups as per DIN 19234 (NAMUR) in two-wire technique and to ... intrinsically safe signal input circuits according to DIN 19234 NAMUR for ...
http://www.aesensors.nl/pdf/kem/EWS.pdf
34 Transformer
Isolated Barrier KF -SR2-Ex1.W.LB Output: Relay ...
Sensors per DIN 19 234 (NAMUR) and mechanical contacts may be used as alarms. The control circuit is monitored for lead breakage (LB). ...
http://www.logicon.com.ua/f/files/1410_5.pdf
Proximity
Sensors Inductive Thermoplastic Polyester Housing Types ...
Output: Namur (DIN 19 234). • 2 m cable. Product Description ... Namur DIN 19 234. Polyester housing. Amplifier relay SD ... available. ...
http://www.acetronic.com/images/EI1202NA.pdf
Courtesy
of Steven Engineering, Inc. • 230 Ryan Way, South San ...
Variable Resistance Output, NAMUR (DIN 19 234). Dual Sensor, Plastic Housing with Potted-In Cable or Quick Disconnect. DS20. Part Number. EmbeddableRated ...
http://stevenengineering.com/tech_support/PDFs/46INDB0160.pdf
Untitled
1 An increase in the upper ambient temperature of the DIN 19234 shaft encoder to 100°C, with a ... 3 The circuit in the DIN 19234 build to be modified. ...
http://www.encoderonline.com/Certificates/DIN_19234/Variation 1.pdf
Untitled
The DIN 19234 and 4-20 mA Tachometer Shaft Encoders are used to indicate the ... 1 An increase in the upper ambient temperature of the DIN 19234 shaft ...
http://www.encoderonline.com/Certificates/DIN_19234/Sira 00ATEX2085 .pdf
Inductive Sensors DC 2-Wire 7.7...9.0 Vdc
NAMUR sensors per DIN 19 234 consist generally of an oscillator, which is damped by the ... (DIN 19 234/DIN VDE 0165) may be used in conjunction with ...
http://www.balluff.com/NR/rdonlyres/AEBBB88C-619F-44F4-A244-37D650D42C40/0/01_136_SC2005.pdf
KCD2-E...
NAMUR /DIN 19 234. - 24 VDC supply voltage. - Standard interface for prevention of signal transmission errors. - Switching status indicator, yellow ...
http://www.darlas.gr/comersus/store/catalog/pf/datasheets/28343.pdf
TURCK MS25-UI Digital To Analog Converters
per DIN 19 234 (term. 9/10). - Nominal operating characteristics. V = 8.2 V, I = 8.2 mA. V = 8.2 V, I = 8.2 mA. - Switching threshold. 1.4 mA Ł I Ł 1.8 mA ...
http://www.clrwtr.com/PDF/TURCK/TURCK-Digital-Analog-Converters.pdf
TURCK
Rotational Speed Monitors
Ł1% (constant temperature. Ł1% (constant temperature. Input Circuit. Nominal operating characteristics (per DIN 19 234). - Voltage ...
http://www.clrwtr.com/PDF/TURCK/TURCK-Speed-Monitors.pdf
StoneL's general
purpose engineered resin SolaR offers ...
Intrinsically safe (DIN 19234). Voltage Range. 6 to 29 VDC ... 44 (2) Namur Sensor Dual Module (DIN 19234). 2N (2) P & F Sensors Switches (DIN 19234) ...
http://www.stonel.com/pdfs/solarlit05.pdf
Valve positioner
EN 60947-5-2 and DIN 19234. Direct switching design. 3-wire system with integrated switching amplifier for direct switching. 2 slotted switch initiators ...
http://ams.cern.ch/AMS/CGSE/Documents/SJTU/Specs/weka_Valve_Positioner/DS824-E_Valve_Positioner_Type_824.pdf
8.8 ISO 8676 /
DIN 961
63.50 107.–. 122.–. 234.–. 234.– ... 13 17 ISO 16 19 ISO 18 22 ISO 21 ... ISO 8765 / DIN 960 d. M 8x1. M 10x1,25 M 12x1,5 M 14x1,5 M 16x1,5 M 20x1,5. M 10x1 M 12x1,25 s. 13. 17 ISO 16 19 ISO 18 ... ISO 4017 / DIN 933 Sz. Zinc plated ...
http://mdmetric.com/fastindx/ua28_30.pdf
SGE985 Limit switch
Inductive limit switch according to DIN 19 234 rsp. NAMUR or three wire system. • Variable switching functions. • Precise switching points through ...
http://www.foxboro-eckardt.com/pdf/PSS_FoxEck/SGE985_1PSS_A_001_en.pdf
Technical
Data Sheet Positioner Type 824 TD_824
2 wire connection to DIN 19234 (NAMUR) for connected switching amplifier in safety version. -. 2 slot initiators. Type SJ3,5-SN ...
http://www.arca-valve.com/download/4/TD_824_gb_2009_12.pdf
I.S. Isolators (DIN Rail Mounting) Switching
Repeater Type 9350
operation of contacts, proximity switches to DIN 19234 (NAMUR), ... 10: to DIN 19234 (NAMUR). Type 9350/10-24-10: for active sources/pulses voltage for ON ...
http://www.mega-ex.com/product_hazardous/Electrical Equipment/STAHL/03036039.pdf
Flow Meter
for low flows of Gases, Liquids and Steam
1 AMD, Hi or Lo Flow Detection. 2 AMD, Hi and Lo Flow Detection. Relay DIN 19234 or NAMUR. Transmitter 4-20 mA, TEH2 (HALLTEC II, 2 wire System) ...
http://www.tecfluid.com/PDF/Catalegs/M-21 angles.pdf
Data Sheet T
8365 E Electric or Pneumatic Limit Switch Type 4746
switch (according to DIN 19 234) for −20 °C to +70 °C. Special version for −40 °C to +100 °C. On request with proximity switches with integral output ...
http://www.swico.com/images/PDF files/T8365E.PDF
20110-EXL-IRU-1 030407-e.FH10
Namur sensor DIN 19234, or EN 60947-5-6, or PTC sensor. Output signal potential free contact. Contact. 230 VAC, 3 A, 60 W, 125 VA, max. 15x106 cyles ...
http://www.beteccontrols.nl/UserFiles/File/Schischek/ExLine/e_20110-EXL-IRU-1_030407.pdf
Technical Data
Sheet T 8383 FOUNDATIONTM Fieldbus Positioner Type 3787
supply as well as data communications use shielded two-wire cables. Isolating switch amplifier for proximity switches acc. to DIN 19234. 6 to 24 V. Bus line ...
http://www.samson.de/pdf_in/t83830ca.pdf
UDS7 EX ENG 02 2003.pmd
Namur DIN 19234, and 1 analog output accuracy class 0,5% f. s.. Teddington AB ... Namur DIN 19234. 2 solid state outputs and. 1 analog output 4...20 mA ...
http://www.teddington.se/datablad/instrument/tryckinstrument/in_500_uds7_ex_datablad.pdf
Proximity Sensors Capacitive
Steel Housing Types DR G, M14, PG 21 ...
Namur DIN 19 234. Delivered with 2 m cable. Specifications. Rated operational volt. (Ue). 8.2 VDC. (UB). 7 to 9 VDC. (6 to 35 VDC, all specifica- ...
http://www.pa-tech.pl/pdf/DR3Gq.pdf
Stampa G4
234-255 -04
DIN 319. Ball knobs. •Ball knobs available in different executions: ... DIN 319-KU-12-M4-C. DIN 319-KU-16-B6-KN. DIN 319-KT-16-M4-C. DIN 319-KU-16-M4-C ...
http://www.rcsproducts.com.au/pdf/Ball_Knobs.pdf
H 4200 /
H 4400 Woltmann Meter Hydraulically balanced rotor for ...
NAMUR DIN 19 234. $ Uo 8 ... 12 V,. Ri 1 kOhm. $ Pulse range approx. 9 ms, closed-circuit current. < 0.7 mA, operating current > 3 mA. ...
http://www.elstermetering.com/downloads/H4200_H4400.pdf
SITRANS F flowmeters
50 Ω (DIN 19234). Number of pulses per revolution of the drive. 10 or 100 ... DIN 19234 of the SIMATIC C 1 system is recommended instead ...
http://www.jadan.com.pl/katalog/pdf/fi01_en/sitransf_r_access_fi01en.pdf
Noninsulated terminals with brazed seam 10 – 70 mm2
DIN 46 234
Noninsulated terminals with brazed seam 95 – 240 mm2 DIN 46 234. Material: Cu-HCP. Surface: tin plated cross flat hole dimensions in mm weight packing- ...
http://www.doublefaith.com/admin/UploadFiles/2009-10/20091010153539131.pdf
Switch
Isolator with Transistor Output KHA6-OT1/Ex1
per DIN 19 234 or NAMUR, ≈ DC 8 V / ≈ 8 mA. Lead breakage (LB) monitoring ... per DIN EN 50 178, design isolation voltage AC 253 V. Conformity to standard ...
http://www.am.pepperl-fuchs.com/pdf/documents/48.pdf
SERIES: DCY-2050,
DCY-2051, DCY-2060 BOILER
DIN 19234 compliance for intrinsically safe. NAMUR sensors. Note: Universal or frequency inputs require different instru- ments. See order code. ...
http://www.indumart.com/DCY-2050-2051-2060.pdf
[PSS EVE0106 A-(en)] SRD992
acc. to DIN 19 234 or NAMUR for connection to switching amplifier with intrinsically safe control circuit 2). Standard version (SJ2-N). . . Option T ...
http://resource.invensys.com/instrumentation/documentation/eiB/eckardt/pss/SRD992_1PSS_A_001_en.pdf
SC-320
(DIN 19234) proximity sensors or limit switches. The sensor will ... Low power sensor signal to DIN 19234. Sensor cable fault indication. ...
http://www.acdc.co.za/rhomberg/docs/SC320d.pdf
SC-300
(DIN 19234). It converts the low current signal of the sensor into a relay switching action. Monitoring the current flow to the sensor, it will detect cable ...
http://www.acdc.co.za/rhomberg/docs/SC300d.pdf
AMBUS® IS
M-Bus pulse collector
AMBUS®IS can read input from a mechanical contact or an open collector or Namur output-circuit (DIN 19234). An input filter can be ac- ...
http://www.aquametro.com/english/pdf/9823e_ambus-is.pdf
SLIMLINE
NAMUR (DIN 19234) proximity sensors or limit switches. The ... Low power sensor signal to DIN 19234. Sensor cable fault indication. ...
http://www.rhomberg.com.au/downloads/SC320.pdf
NELES SOLAR
NJ2-V3-N, NAMUR NC, Conforms to DIN 19234. Nominal voltage 8 VDC. Target off: I > 3 mA, Target on: I < 1 mA ... Namur sensors confrom to DIN 19234 standard ...
http://www.automaatika.ee/web/pdf.nsf/6bd63030d3d55414c2256f7900385d71/6c710e153b635612c22571c6004ee9e5/$FILE/7SOL20EN.pdf
YOKOGAWA
DIN 19234 (NAMUR) in. FAIL SAFE version. Ambient temperature. : -40 ºC to +100 ºC. Other specifications. : See type SJ 3,5-N. Available with options /K1. ...
http://www.maring.cz/docu/EN_GS_TI/prutok/GS1R1B3.pdf
7 SOL 20 EN
DIN 19234. Nominal voltage 8 VDC. Target off: I > 3 mA, Target on: I < 1 mA. DUAL MODULE SYSTEM. The Neles SolaR platform is available with the dual module ...
http://valveproducts.metso.com/neles/TechnicalBulletins/en/7SOL20EN.pdf
1 2
