1
Charging characteristic:
According to DIN 41773. − Generally: A discharge of the battery after the end ... according DIN 41773. For fluctuations of mains voltage of ± 10% and for ...
http://www.sonnenschein.org/PDF files/IUIa_GiV_engl.pdf
HOPPECKE
DIN 41773 Part 2 (IU characteristic). DIN 41776 ( I characteristic). In order to avoid overloading the electric circuits and contacts and to prevent unac- ...
http://www.allnesales.com/hopp-fnctoperating.pdf
HOPPECKE
DIN 41773 Part 2 (IU-characteristic). DIN 41775 (W-characteristic). DIN 41776 (I-characteristic). Depending on battery application the following ...
http://www.allnesales.com/hopp-fnc-operating.pdf
Rectifiers
λ ≈ 1, EN61000-3-2 λ ≈ 1, EN61000-3-2. Output. IU-characteristic, DIN41773. IU-characteristic,. DIN 41773. IU-characteristic,. DIN 41773. Rated voltages ...
http://www.eltek-valere.de/fileadmin/produkte/Gleichrichter/Aktuell/EV_Gleichrichter_E_V12_einzelseiten.pdf
! Batteries / cells are heavy! Ensure adequate mounting security
...
DIN 41773 must be used. They are to be set so that the average cell voltage is 2.275Vą0,005V. 2.4 Supplementary and Equalizing charge ...
http://www.ssb-battery.com/technik/Bedienungsanltg/BA_SBH-ABC-ABLFT_engl.pdf
Products Rectifiers
λ ≈ 1, EN 61000-3-2. Output. IU-characteristic, DIN 41773. IU-characteristic, DIN 41773. IU-characteristic, DIN 41773. Rated voltages. 24 V, 48 V, 60 V 4 ...
http://www.vuh.de/fileadmin/produkte/Gleichrichter/Gleichrichter_Englisch.pdf
Battery Chargers
ZBDM High Power
Charging values consistent with the DIN 41773 Part 1 standard, ... DIN 41773 Part 1. Static power processors, IU semiconductor rectifiers to charge ...
http://www.medcom.com.pl/dl/MEDCOMZBDMEN0303.pdf
Yuasa
Battery (Europe) GmbH Operating instruction for valve ...
their limit values according to DIN 41773. (IU-characteristic). According to the charging equipment specification and characteristics, alternating currents ...
http://www.yuasa-battery.de/englisch/download/allg_beh_e.pdf
Power Safety
characteristic line to DIN 41772/DIN 41773. It is a pre-wired unit. The connections can be accessed from the front panel. The con- ...
http://www.aegps.com/aeg/export/sites/aegpowersolutions/en/products/downloads/Downloads/Modular_Industrial_Power_Supplies/AC7000_Analog_EN.pdf
Power Safety
IU characteristic to DIN 41772 / DIN 41773. MONITORING AND INDICATION. Mains monitoring. Phase failure, self-acknowledging. Under-voltage with switch-off, ...
http://www.aegps.com/aeg/export/sites/aegpowersolutions/en/products/downloads/Downloads/Modular_Industrial_Power_Supplies/AC7000_24x48x60V_EN.pdf
OpInstruct_Classic Solar
tions under DIN 41773. They are to be set so that the average cell voltage is as in table 1 and the electrolyte density should not decrease over a ...
http://www.exide-nordic.com/pdf/manualer/Classic Solar (english).pdf
GA EPzV 56025017 e
2.2 Charging. Only direct current must be used for charging. Charging procedures according to DIN 41773 and DIN 41774 must only be applied in the ...
http://www.exide-nordic.com/pdf/manualer/Sonnenschein_EPzV (english).pdf
IGBT rectifier for stationary battery systems
1, rectifier is short circuit proof. Ripple. [%]. ≤ 5, p – p without battery. Charging characteristic float / boost / equalize. IU in acc. DIN 41773 ...
http://de.benning.de/fileadmin/content/pdf/784419_transotronic_gb.pdf
Industry / Telecom
1: IU-characteristic, DIN 41773 for lead acid batteries. [V/C]. IN [%] float charging ... DIN 41773 (Fig. 1 + 2). The excellent dynamic performance of ...
http://de.benning.de/fileadmin/content/pdf/10002228_GLR_ADC_gb.pdf
Charger Switch Mode (Three Phase)
BETTER THAN 1%. RIPPLE WITHOUT BATTERY. LESS THAN 100 mV. WEIGHTED NOISE. 2 mV. PARALLEL OPERATION. CHARGING CHARACTERISTIC. DIN 41773. CHARGING MODES: ...
http://www.tobb.org.tr/rehber/iran/Charger Switch Mode (Three_Phase).pdf
Stabilized
Battery Charger Power Supply
Characteristics acc. to DIN 41773. • Mains transformer acc. to VDE 0551. Application .... Acc. to DIN 41773 (< +/- 1% tolerance) and DIN 57510 ...
http://www.dsl-electronic.de/pdf/uk/E0AL1024.pdf
Primary switched
battery charger Power supply 5A 24V
IU – Char. acc. to DIN 41773 (appr. +/- 1% Tolerance) and DIN 57510 with reduced. Current (Wa) in the area of final charging voltage (appr. 3,5% of setting) ...
http://www.dsl-electronic.de/pdf/uk/E0GL0524.pdf
Marathon
L Operating Instruction 41410 Stationary, valve regulated ...
DIN 41773 must be used. They are to be set so that the average cell voltage is 2.27 Vpc± 1%. 2.4 Equalizing charge. Because it is possible to exceed the ...
http://www.elektrotec-berlin.de/download/eng/GB-MarathonL.pdf
Sonnenschein
A 400 Operating Instruction 31400 Stationary valve ...
limit values according to DIN 41773 (U-characte- ristic). According to the charging equipment spe- cification and characteristics alternating currents ...
http://www.elektrotec-berlin.de/download/eng/GB-A400.pdf
Kazakhstan Gost Russia Underwriters Laboratories Inc. ® USA
maintenance status of charge on side: - trimmer for adjustment of end charge voltage. 1. RAL2E12 (2A - 12VDC). CHARGE PROFILE. IU (DIN 41773 standards) ...
http://www.revalco.it/english/catalogues/news_2009gb/pdf/news 2009 gb.pdf
Charge technology for dryfit –
obligation. This specification does not concern legal or safety standards. 1 Charging characteristic: IUa (according to DIN 41773). Regime. Switching ...
http://www.batteriunion.se/blockbatterier/pdf/laddkurva_tractionblock_IUA_DIN41773_000417.pdf
Primary Switched Battery Charging and Power Supply Unit
Charging characteristics acc. to DIN 41773. Application: The battery charging and power supply unit GL1024 is used for charging high-quality lead or nickel- ...
http://www.dsf-tech.com/upload/proddocspdf/proddocspdf_2_652.pdf?PHPSESSID=83f23eeec7520e61b54442aa32df60c2
Primary Switched Battery Charging and Power Supply 40A
DIN 41773. Application: The battery charging and power supply unit ... IU – Char. acc. to DIN 41773 (appr. +/- 1% Tolerance) and DIN 57510 mit reduced ...
http://www.dsf-tech.com/upload/proddocspdf/proddocspdf_2_654.pdf?PHPSESSID=94667e1b1c7618c43cb7ce056d193591
AC7000 -e
IU characteristic curve to DIN 41772/DIN 41773. Mains-side monitoring systems. Phase failure; overvoltage/undervoltage with shut-off, auto-acknowledgement ...
http://www.extor.hu/egyenaramu_rendszerek/telekom_renszerek/ac 7000 analog en.pdf
AEG_009 AC 2000 E (Page 1)
on an IU characteristic line to DIN. 41772/DIN 41773. It is supplied fully ready for installation. The connection points are accessible from the front. ...
http://www.extor.hu/egyenaramu_rendszerek/ipari_rendszerek/fiokos rendszeru tapegysegek/ac 2000 analog en.pdf
Capitolo
18
- Related articles
http://www.technikagkm.hu/Lovato/pdf/battery chargers.pdf
ELECTRO
3-HF
Charging curves IUIa as per standard DIN 41773 for normal charge (10 to 14 h) or fast charge (7 to 8 h). ELECTRO 3-HF is simple. ...
http://www.nordyne-normand.com/docs/en/DOC_ELECTRO_3-HF_AN.pdf
Thyristor-controlled
power supplies and battery chargers
IU characteristic acc. to DIN 41773 and 41774. ■ manual selection of charging characteristic. (float / equalize / boost) ...
http://www.schaeferpower.com/pdf/thyristor.pdf
Compact-Power Rackline™ 12CP165
CC-CV charge current according to DIN 41773. Unlimited, otherwise 45 A max. if T > 30 °C. Float voltage compensation in function of temperature ...
http://www.isaac.supsi.ch/isaac/Energia nella costruzione/formazione/Formazione continua/Corso Penta Project/materiale corso/Modulo - Energia fotovoltaica/presentazioni e allegati/oerlikon 12cp165.pdf
Alle
Blocklines en 2007-04-27.indd
by E Data - Related articles
http://www.oerlikonbatt.se/PDF Cp En/B_6CP155_EN_20070514.pdf
Alle
Racklines en 2007-06-13.indd
Float voltage setting according to DIN 41773. 2.27 Vpc at 20 to 25 °C (68 to 77 °F). Float voltage with daily discharge cycles ...
http://www.oerlikonbatt.se/PDF Cp En/R_12CP98_EN_20070613.pdf
Battery Charging
Power Supply Unit Power-fail Relay
Characteristics acc. to DIN 41773. • LED-monitoring for “Power OK” .... Acc. to DIN 41773 (< +/- 1% tolerance) and DIN 57510 ...
http://dsl-elektronik.com/pdf/uk/E0AL1024-PF.pdf
Telecom
IU in accordance with DIN 41773. < 2 mV in accordance with CCITT 0.41. 90 %. 0 ũ 40 °C. IP 20. 758 x 534 x 470. Modular DC Power Supply Systems BLT 150, ...
http://marpex.bg/files/upload/8ec4ee538b4af85310726f979a4c6004843de6f7.pdf
Power Safety
IU characteristic line to DIN 41772 / DIN 41773. It is a pre-wired unit supplied ready for installation. The connections are acces- ...
http://www.aegpowersolutions.com/aeg/export/sites/aegpowersolutions/en/products/downloads/Downloads/Modular_Industrial_Power_Supplies/AC2000_EN.pdf
Power Safety
DIN 41772 / DIN 41773. Es ist eine anschlussfertige Einheit. Die. Anschlüsse sind frontseitig zugänglich. Die Bedien- und Anzeige- ...
http://www.aegpowersolutions.com/aeg/export/sites/aegpowersolutions/en/products/downloads/Downloads/Modular_Industrial_Power_Supplies/AC2000_DE.pdf
Oper_instr. Sonnen Solar e
DIN 41773 must be used. They are to be set so that the average cell voltage is as follows. (within temperature range 15 to 35° C): SOLAR, SOLAR BLOCK: ...
http://www.produktinfo.conrad.com/datenblaetter/100000-124999/110795-da-01-en-Dryfit_Solarakku.pdf
STROMVERSORGUNGSGERÄTE MIT IU-KENNLINIE NACH DIN
41773
IU nach DIN 41773, umschaltbar auf IUI-Kennlinie. Ladespannung: 2,4V/Z ±1% (statisch) bei Bleizellen, 1,55V/Z ±1%. (statisch) bei NiCd-Zellen ...
http://www.maasewers.de/PDF-Dateien/Gleichrichteranlagen/IU Gleichrichter.pdf
AEG_009/DC
2000 E (Page 1)
on an IU characteristic line to DIN. 41772/DIN 41773. It is supplied fully ready for installation. The con- nection points are accessible from the front. ...
http://www.metric.no/uploads/pdf/stromdok/Nr.1 DC_2000.pdf
Compact-Power
Rackline™ 12CP30
CC-CV charge current according to DIN 41773. Unlimited, otherwise 10 A max. if T > 30 °C. Float voltage compensation in function of temperature ...
http://www.rps-msk.ru/docs/rackline.pdf
Charging and Power Supply Units
to DIN 41773. Continuous charging voltage. 2.23-2.27/1.43 (Pb/NiCd) V/ cell +/- 1%. Boost charge voltage. 2.40/1.55 (Pb/NiCd). V/ cell +/- 1% ...
http://www.schuster-energie.de/ENGLISHBrochureIUProf_Control_04_08.pdf.pdf
Alle
Helionpower en 2007-11-22.indd
by E Data - Related articles
http://www.avalon-multimedia.de/avalon-ebay/12HP110english.pdf
SWITCH-MODE DC 2000
IU characteristic line to DIN 41772/. DIN 41773. It is supplied fully ready for installation. The connection points are accessible from the front. The ...
http://www.hansbuch.dk/files/DC_2.pdf
Gebrauchsanw. verschlossen EN
DIN 41773 must be used. They are to be set so that the average cell voltage is. 2.25 V ± 1%. 2.4. Equalising charge. Because it is possible to exceed the ...
http://www.hoppecke-us.com/pdfs/lead_acid_info/Operating_Instructions_sealed_stationary_lead_acid_batteries_English_12_02[1].pdf
Note: If
AquaGen€ vent plugs are sup- plied do not fit onto the ...
DIN 41773 Part 2 (IU characteristic) constant current/constant voltage characteristic. DIN 41775 (W characteristic) declining current characteristic ...
http://www.hoppecke-us.com/pdfs/FNC_A_Oper_Ins_US.pdf
Operating Instructions
DIN 41773 must be used. They are to be set so that the average cell voltage is 2.25 V. ± 1%. 2.4 Equalising charge. Because it is possible to exceed the ...
http://www.hoppecke.de/content/download/272/1610/file/Gebrauchsanweisung_fuer_verschlossene_ortsfeste_Bleibatterien_en0109.pdf
Maintenance and
Handling Instructions
IU-characteristic curve (DIN 41773 Part 2). Here the rising battery charging voltage is limited to a value of 1,55 to 1,65 volts per cell. On reaching this ...
http://www.nrsga.com/PDF/Maintenance-Handling.pdf
OpIinstruct_Sonnen
Solar
All charging must be carried out acc. to DIN. 41773 (IU-characteristic). Recommended charge voltages for ... DIN 41773 must be used. They are to be set so ...
http://www.exide.dk/pdf/manualer/Solar (english).pdf
Gebrauchsanweisung
24 Kopie 1
res in accordance with DIN 41773-1 and DIN 41774 are per- mitted. Only connect the battery assigned to a charger, sui- table for the size of battery, ...
http://www.powercell.co.uk/PDF files/WF200 Instructions.pdf
IGBT
rectifier for stationary battery systems
IU characteristic curve (according to DIN 41773) for standby parallel operation with NiCd or lead acid batteries (fig. 3). For ...
http://www.mothek.fr/Redresseurs/Indus/transotronic_gb.pdf
Power Safety
characteristic line to DIN 41772/DIN 41773. It is a pre-wired unit supplied ready for installation. The connections are accessible from the front panel. ...
http://www.aegpss.de/aeg/export/sites/aegpowersolutions/en/products/ModularIndustrialPowersupplies/DCDC/20DC2000/sheets/DC2000x.pdf
1 2