Microsoft
Word - PAH conduit DB DIN 5510 Apr-06.doc
DIN 5510 part 2 (draft 09/2003). Preventive fire protection in railway vehicles .... Assessment pursuant to DIN 5510, part 2: Flammability class: S 4 ...
http://www.staport.pl/uploads/adaptaflex/certyfikaty/1251a.pdf
Microsoft
Word - PIH conduit DB DIN 5510 Apr-06.doc
DIN 5510 part 2 (draft 09/2003). Preventive fire protection in railway vehicles. Part 2 Fire behaviour and fire side effects of materials and parts; ...
http://www.staport.pl/uploads/adaptaflex/certyfikaty/1248a.pdf
EURO-COMPOSITESŻ Qualifications References
Classification according to DIN 5510 part 2. •. Flammability class: ... Classification smoke gas toxicity DIN 5510-2 (lay-out sketch ...
http://www.euro-composites.com/SiteCollectionDocuments/_523-01e.pdf
Coating and Coating process Spraying process spraying process
...
DIN 75200 - MVSS 302 according to. DIN 5510 T.2 - S4, SR2, ST2. DIN 5510 T.2 - S4, SR2, ... DIN 5510 T.2 - S3, SR2, ST1. IMO Resolution MSC.61 ...
http://www.iacgroup.eu/fileadmin/user_upload/files/Products/Technical_Market/Data_Sheets_English/TD_Structure_borne_sound_damping_NEW.pdf
BÜFA-FIRESTOP® AND OTHER FIRE PROTECTION SYSTEMS
DIN 5510. Gelcoat in brush- and spray consistency. S4,. SR2, ST2 DIN 5510 ... SR2/ST2 DIN 5510, preaccelerated. All BÜFA-Firestop® products are halogen-free.
http://www.buefa.de/buefa/intranet/buefa_icmfl_en.nsf/vw_icons/Firestopenglisch/$file/Firestopenglisch.pdf
BÜFA-FIRESTOP® FIRE PROTECTION SYSTEMS
DIN 5510. S4/SR2/ST2. 26-28 mm sandwich. DIN 4102. B 1. 4 mm laminate. DIN 5510 ... DIN 5510. S4/SR/ST2. 4 mm laminate. BS 6853 cat 1b. 4 mm laminate ...
http://www.buefa.de/BUEFA/INTRANET/BUEFA_ICMFL_EN.NSF/vw_icons/Brandschutz englisch1/$file/Brandschutz englisch.pdf
R82 E 11 08
DIN 5510/2. Flammability. S4. S4. DIN 5510/2. Smoke density. SR2. SR2. DIN 5510/2. Dripping. ST2. ST2. DIN 5510/2 / DIN 53438-2. Edge flaming ...
http://www.atlcomposites.com.au/files/products.cores.airex__foam.r82_high_performance/r82_data_sheet_1_.pdf
T90 E 10 08
DIN 5510/2. Flammability. S4. S4. S4. S4. DIN 5510/2. Smoke density ... DIN 5510/2. Dripping. ST2. ST2. ST2. ST2. DIN 5510/2 / DIN 53438-2 Edge flaming ...
http://www.atlcomposites.com.au/files/products.cores.airex__foam.t90_easy_processing/t90_data_sheet.pdf
Anforderungsspezifikation
„Brandsicherheit bei Schienenfahrzeugen“
Tabelle 5 DIN 5510-2 für Fahrzeuge der Brandschutzstufe 2 gem. DIN 5510-. 1 erfüllen. ... Bauteilen“ in der DIN 5510-2 in Tabelle 5 aufgelistet. ...
http://www.oebb.at/de/B2B_Online/AGB/A01_10-5-10-010.pdf
PAV0 PA-FF PPDA PP-AC SA (64° Shore-A)
Vorbeugender Brandschutz (nach DIN 5510, Teil 2). Preventive Fire Protection (according to DIN 5510, Part 2). PA-FF. Vorbeugender Brandschutz (nach Def Stan ...
http://www.gulfoilandgas.com/webpro1/GenData/10807/PDF/Stauff_Anglia.PDF
Bygnings
standarder
DIN 5510 – 2, klasse S1. Vorbeugender Brandschutz in Schienenfahrzeugen. Teil 2: Brennverhalten und Brandnebenerscheinungen von werkstoffen und Bauteilen. ...
http://dbi-net.dk/media/db21d1657ff24799873d6a7fc24bcb93.pdf
Lab services for train interior components
to DIN 5510-2. The test laboratory was also audited by the Swiss. Federal Office of Civil Aviation ... fication and requirements to DIN 5510-2 : 2009-05. ...
http://www.lantal.com/data/BE9A59B0-14C2-626D-C2DBD056F1302D24/Labordienstleistungen Bahn_e.pdf
Phonkiller® 2026 D (210081)
Fire behaviour (DIN 5510,. Part 2 resp. DIN 54387): S4, SR2, ST2. Dielectric loss factor according to DIN EN ISO 6721, Part 3,. 200 Hz at two-times ...
http://www.lackfa.com/pdf/en/produkte/entdroehungsmittel_2026d.pdf
untitled
hicles according E DIN 54837 : September 2003. Classification according E DIN 5510-2 : September 2003. Customer UNION FOAM SPA 10. June 2005. Mrs Orienti ...
http://www.unionfoam.it/pdf/certificati/itflex/burning behaviour E DIN 54837.pdf
Innovative
RADOX® railway cables
RADOX® railway cables. «Meets fire performance requirements according to DIN 5510-2» ... stock DIN 5510-2, BS 6853 and NF F 16-101 and the ...
http://www.aste.pl/images/dokumenty/7060_2009-09-07_en.pdf
Keeping technology moving
Compliant with railway regulations DIN 5510 (S4, SR2, ST2). Compliant with regulation NF F 16.101 (F2/M2 at 2.00 and 4.00 mm). V0 - 1,5 [mm] and V1- 1[mm], ...
http://www.fist.si/db/fist/File/Sabic/Railway_Interiors.pdf
Product Description Features Instructions for Use MTM®82S-C ...
DIN 5510-2. Dripping. ST2. Availability. MTM82S-C prepregs are available in a wide range of reinforcements. Out Life and Storage ...
http://www.advanced-composites.co.uk/data_catalogue/catalogue files/pds/PDS1244-MTM82S-C-Issue-1.pdf
Baltique California 117 EN 1021-1,2 ISO 8191-1,2 Bolla EN 1021-1,2
...
E DIN 54837/E DIN 5510-02. Elmofrost. California 117. EN 1021-1,2. ISO 8191-1,2 ... DIN 53438. Part 3. EN ISO. 1716:2002. E DIN 5510-2. ISO 3795:1989 ...
http://www.elmoleather.com/images/cmDocuments/Brandmatris070130.pdf
elmoo
E DIN 54837/E DIN 5510-02. Elmogrand. | California 117 EN ISO 1021 -1,2 ISO ... BS 5852:1990 crib 5. BS 5852:1990 crib 7. E DIN 5510-2. DIN 53438 Part 3 ...
http://www.elmoleather.com/images/cmDocuments/Brandcert071119.pdf
Test report No. P60-09-0455
Objective of test: Evaluation according to DIN 5510 part 2 (05/2009). Test results: Inflammability class: S 3. Smoke development class: SR 2 ...
http://isoflex.webdoc.nu/files/certifikat/MX-T10, S3, ST2 P60-09-0455.pdf
Flammstop®
with DIN 5510, Part 2. - fulfils the requirements of Airbus in accordance with ABD 0031 and the regulations for smoke density ...
http://www.gel-top.dk/cgi-files/mdmgfx/file-599-117165-14872.pdf
Test report 06/51 9e
flame propagation according DIN EN 60332-1-2 and EN DIN 5510-2, Tab. 6 respectively. Michael Halfmann. (Head of Fire Testing). Bayer Industry Services ...
http://www.hubersuhnerinc.com/hs-p-rf-cab-gr-std-rlw-din5510_2-flame-gx07272_en.pdf
Corianо Solid Surface
(14) test report P60-08-0018 (test according to DIN 54837, classification according to DIN 5510-2) from RST-Germany/01-2008 ...
http://www2.dupont.com/Corian/sq_AL/assets/downloads/documentation/corian_specdata_en.pdf
Lab services for train interior components
fication and requirements to DIN 5510-2: 2003/2007. The test investigates the burning behavior and sec- ... The test is performed pursuant to E DIN 5510-2 : ...
http://transportationfashion.org/data/BE9A59B0-14C2-626D-C2DBD056F1302D24/Lab services for train.pdf
Exova
Brandhaus - Rail Fire Testing
5510-2 and TL der Deutschen Bahn AG and. UIC 564-2. •. Testing of subway and streetcar seats, DIN. 5510-2. •. Testing according to DIN 5510-2: ...
http://www.warringtonfire.net/ContentAttachments/892.pdf
Corian® Solid Surface
(14) test report P60-08-0018 (test according to DIN 54837, classification according to DIN 5510-2) from RST-Germany/01-2008 ...
http://www.corian.co.uk/Corian/en_GB/assets/downloads/documentation/corian_specdata_en.pdf
11. June 2008
DIN 5510-2: 2007. Preventive fire protection in railway vehicles - Part 2: Fire behaviour and fire side effects of materials and parts - Classification, ...
http://www.nationalgummi.com/pdf/12/DIN 5510-2 (EPDM 211161) 2mm.pdf
AIREX T90 EASY PROCESSING STRUCTURAL FST FOAM
DIN 5510/2. Flammability. S4. S4. S4. S4. DIN 5510/2. Smoke density ... DIN 5510/2. Dripping. ST2. ST2. ST2. ST2. DIN 5510/2/DIN 53438-2 Edge flaming ...
http://files.alcancomposites.com/downloads/2_3_en_/t90_data_sheet.pdf
Certifications
DIN 5510. S4/SR2/ST2. SIEMENS AXIVA. 2003-1870. NUDEC® PET UV 2-5 mm. NFP 92-507. M2. PREFECTURE DE POLICE. 399/2001. NUDEC® PET UV Opal 2-4 mm. NFP 92-507 ...
http://www.cadshelters.co.uk/pdf/PET-fire-cert.pdf
.. J1
flame propagation according DIN EN 60332-1-2 and EN DIN 5510-2, Tab. 6 respectively. V. Michael Halfmann. {Head of Fire Testing). Bayer Industry Services ...
http://www.hubersuhner.com.br/co-br/hs-p-rf-cab-gr-std-rlw-din5510_2-flame-gx07272_d_04_en.pdf
Door Module • ISO
834-1 (15 min) • DIN 5510 - Part 2 - A2 - 15
Internet: http://www.sus-mhl.de. Door Module. Customer: Alstom LHB (Project X60). Fire Barrier according to: • ISO 834-1 (15 min). • DIN 5510 - Part 2 - A2 ...
http://www.sus-mhl.de/info/08 tuermodul_ENG.pdf
Airflex Special Hoses are light weight and highly flexible
DIN 5510-S4/SR2/ST2. VMQ on glass fabric. FAR § 25.853(a), ABD 00031. Main Applications : Ventilation, Heating, Extraction, Air-Intake, Drainage ...
http://www.mst-gmbh.de/DOCUMENTS/MST_Technical__Data_Sheets_E.pdf
Engineering Plastics – Fire-safety aspects – Brochure
The requirements in DIN 5510-2 34 pertaining to the fire behavior of the materials and components to which passengers have access ...
http://www.plasticsportal.net/wa/plasticsEU~en_GB/function/conversions:/publish/common/upload/engineering_plastics/EngineeringPlastics_FireSafety.pdf
Typical Physical Properties
DIN 5510-2. B1. S4/SR2/ST2. CSE RF-2-75A/ RF3-77. Class 1. NF F 16-101 & 102. M2, F1. Property. Test Method. Conditions. Units. Value. Physical. APET. PETG ...
http://www.perspex.co.uk/documents/technical/physical-properties/Polyester-APET-and-PETG.pdf
Railway sensors
Railway sensors. Temperature sensors, speed sensors and components for rail vehicles. • Fire behavior acc. to DIN 5510. • Resistant to shocks acc. to DIN ...
http://www.businessonrails.german-pavilion.com/gp/brs09/exhibitors/dateien/05_Railway_sensors_and_products_EPHY-MESS.pdf
АВСТРИЯ 1 ON ÖNORM B 1300-1 Safety testing of objects for contract
...
26 DIN. 03900323. Static guarding and mobile patrol services - Requirements. 27 DIN. DIN 5510-2. Preventive fire protection in railway vehicles - Part 2: ...
http://www.bds-bg.org/images/upload/Notifications/Notifications_98_34_2007_bg/Notifications_98_34_09_07.pdf
Money-saving Design Quality
with DIN 31000). Test result DIN 5510. Urea fire test. Test DIN 54837. Internal Test in accordance with DIN 19516:2003. Internal Test in accordance ...
http://www.pressalit.com/NR/rdonlyres/F52CCA87-9D81-45D9-B4B5-A811FEE5BFEC/0/Projektbrochure_4s_exp.pdf
2009_08_24_Standards
Overview
Compliance with DIN 5510 part 1 (1998-10) and part 2 (2009-05), fire protection class 3,. Dielectric test according to DIN EN 50155: ...
http://www.gsp-berlin.de/standards.pdf
Dia 1
DIN 5510 / DIN 54837 DB-Brandschacht. Docket 90A / ASTM E162 Radiant panel test. NF P 92-507 Epiradiateur test. NF X 70-100 / NF X 10-702 Smoke toxicity / ...
http://www.ukintpress-conferences.com/conf/rail07/pdf/day3/michaelstockman.pdf
11.00 Beth Dean
6 Nov 2008 ... DIN 5510 provides the Reaction To Fire requirements. Current issue of DIN 5510 does not include toxicity test method ...
http://www.ukintpress-conferences.com/conf/08rail_conf/pdf/Day_3/Beth_Dean.pdf
NEW EDITION
standard DIN 5510-2. Being situated in Ense (Ruhrgebiet-area)/Germany, ... DIN 5510 fire protection standard, DIN EN ISO 9001 quality assurance, etc. ...
http://www.marineplantsystems.com/web/Cleemann_download_files/edition_08.pdf
SEATING SYSTEMS FOR WORKBOATS
protection standard DIN 5510-2. The chair-systems fulfill all German and international safety and quality requirements, e.g. Germanischer Lloyd ...
http://www.marineplantsystems.com/web/Cleemann_download_files/Workboat 2009.pdf
Verint
RP 500 Series
EN 50121 -3-2; DIN 5510. Verint RP 506 K. 1/3" Sony Exview Interline CCD. PAL: 752 x 582. NTSC: 768 x 494. 470 TV Lines. 0015 lux at the sensor / ...
http://www.periprotect.com.ua/products/verint/pdf/RP500_d.pdf
Exolit® for Thermosets
DIN 5510. 15-25 phr Exolit AP 422. Class S3/S4, SR2, ST2, 4 mm with polyamine hardener. Additional comments. Exolit AP 422 can be replaced with ...
http://pa.clariant.com/C125720D002B963C/B80D1F176DAB7D54C12572810059799F/$FILE/DA4003E_0906_BR_ExolitforThermosets.pdf
August 30, 2005
German Standard DIN 5510-2: Preventive fire protection in railway vehicles-Part ... DIN 5510/2 Classification: Flame Retardant Braided Expandable Sleeving ...
http://www.panduit.com/groups/MPM-GAWA/documents/ProductBulletin/CMSCONT_034275.pdf
www.panduit.com PANDUCT® Type TMC Wiring Duct Global Passenger
...
German Standard DIN 5510-2: Preventive fire protection in railway vehicles-Part 2: Fire behaviour and fire side effects of ...
http://www.panduit.com/groups/MPM-LP/documents/Compliances/093509.pdf
Technology Solutions
DB DIN 5510 § 2 & 54837: S4,SR2,. ST2; UNI; ASTM E 662 - ASTM E. 162; Raw material UL 94 V0. ✓. Material: UL 94 V0 Rated. Polyester ...
http://www.federalmogul.com/NR/rdonlyres/A5898193-A380-4EF2-8328-2CF025317DA8/0/ITSeBrochure.pdf
Grafica1.cdr
DIN 6701-n anti-graffiti. NFF31 112. NF F 19 483. SNCFCP1 fire and smoke. NF F 16-101. SNCF STM-S-001. UIC 564-2. BS 6853. DIN 5510. DIN 5510-1.2 ...
http://www.sessaklein.com/pdf/brochure_sks.pdf
Test
Report
DIN 5510 Part 2. Result: Surface Ignition. DIN 5510 Part 2. F1 /15.0mm. Remarks: This report is valid for 3 years after the execution of the test. ...
http://www.tecnodist.ch/images/SKYPAN 550 F1 eng.pdf
PAtMEKJI PRODUCT CERTIFICATION
8410, WP29, 95/28/EEC, DIN 75200. 5j$ Trains. KlflJK): BS 6853 fèg(GRE): DIN 5510-2. ^S(FRA): NF F 16-101. BfeS(EU): EN 45545-2 ...
http://www.sgs.com/sgsdocuments/sgs-hardlines-flammability-testing-services-en-zh-09.pdf
1 2