pro clima
SOLITEX
DIN EN 12572. < 0,10 m. Water-resistance. DIN EN 20811 waterproof water column > 2500 mm. Fire class. DIN 4102. B 2. UV stability and outdoor exposure ...
http://download.proclima.com/en/int/solitexSystem.pdf
pro clima
SOLITEX
Stiepes izturība naglu vietās DIN EN 12310-1. > 300 N sd-vērtība. DIN EN 12572. < 0,10 m. Ūdens necaurlaidība. DIN EN 20811 ūdens staba spiediens ...
http://download.proclima.com/lv/Solitex_LV.pdf
Pro Clima DA-S
Thickness. Steam diffusions. Resistance Factor sd-Value. Fire rating. Head of Water. DIN EN 1849-2. DIN EN 12572. DIN EN 12572. DIN EN 13501-1. DIN EN 20811 ...
http://www.ecologicalbuildingsystems.com/workspace/downloads/Pro-Clima-DA-S.pdf
Handlungshilfe
„Klettern in der Schule“ Unfallkasse Freie ...
Die Kletterwand wird gemäß der Norm DIN EN 12572 geplant und errichtet ... DIN EN 12572 liegt vor. □. □. Der Fallraum vor der Wand ist geeignet: ...
http://www.unfallkasse.bremen.de/pdf/hh_klettern3.pdf
DACO-KSD-R
Flexibility at low temperatures. DIN EN 1109. °C. - 20. Water vapour transmission properties. DIN EN 12572 m sd ≥ 1.800. Caloric value according. DIN 51900 ...
http://www.georgboerner.de/fileadmin/media/Website/Inhalt/Produktdatenblaetter/industriedach/PDB_DACO-KSD-R_684-1-2.pdf
DACO-KSD-R Kaltselbstklebende, brandlastarme Polymerbitumen ...
Diffusionsäquivalente. Luftschichtdicke. DIN EN 12572 m sd ≥ 1.800. Brandverhalten. DIN EN 11925-2. Klasse E nach DIN EN 13501-1. Heizwert. DIN 51900 ...
http://www.georgboerner.de/fileadmin/media/Website/Inhalt/Produktdatenblaetter/industriedach/PDB_DACO-KSD-R_684-1.pdf
Fire protection and building board applications in industry
DIN EN 12572. Thermal conductivity 10, dry. 0.173 W/(m•K) accord- ing to DIN EN 12664. Thermal resistance 10, dry. 0.07 (m2•K)/W accord- ing to DIN EN 12664 ...
http://www.fermacell.de/downloads/deu/broschures/AE_Fire_protection_and_building_board_applications_in_industry.pdf
ISO-BLOCO 600
DIN EN ISO 12572. µ < 100. Long term stability. 10 year performance guarantee* sd-value. DIN EN ISO 12572. < 0,5 m for 50 mm width ...
http://www.iso-chemie.com/material/product-data-sheets/iso-bloco-600-premium-edition.pdf
ISO-BLOCO 300 "premium edition"
DIN 7715 T5 P3 requirements fulfilled. Building material class. DIN 4102. B1 (fire resistant). Water vapour diffusion resistance. DIN EN ISO 12572 ...
http://www.iso-chemie.com/material/product-data-sheets/iso-bloco-300.pdf
Forschungsinstitut für polymère Baustoffe Dr. R. Stenner GmbH
...
in accordance with DIN EN ISO 7783-2 and DIN EN ISO 12572 respectively. RECEIPT OF SAMPLES. On 2002-12-12 the following sample was received at the Polymer ...
http://fi.navigator.maxit-cms.com/media/58/Navigator/uploadfiles/test reports/water permability.pdf
Buch 1.indb
rungspunkte gemäß DIN EN 12572 mit 10 kN (1 Tonne) nachgewiesen werden müssen. ... Grundsätzlich müssen alle Kletteranlagen der DIN EN 12572 für künstliche ...
http://shoptimax.de/out/oxbaseshop/html/0/images/wysiwigpro/549-558_72_ND.pdf
STS
Directory
DIN 53312, SOP CA-2000. Determination of released nickle. 7.VO zur Änderung der BGVO. Anlage 5A zu § Abs. 4 (Anlage 9). § 35 LMBG 82.02.7 (DIN EN 12572) ...
http://www.strtest.ch/Zertifikate/182stsvz - en.pdf
TITLE
A compilation of international standards for testing of ...
DIN, EN ISO 12572 Building materials- Determination of water vapor transmission properties (ISO/DIS. 12572:1997) German version prEN 12572:1997 ...
http://www.prodomea.com/Literature/doc/hu_internstandard.pdf
Technical
Datasheet
DIN EN 12664. DIN EN 14581. DIN EN ISO 12572. DIN EN 318, edition 5, 1998. E DIN EN 438, 02/02 part 2/12. DIN 53 387, 04-'89. LMBG § 31 ...
http://www.lghimacs.be/pdf/TechSpecsGB.pdf
Fraunhofer
Hof ter Vleestdreef, 3, 1070 Brüssel. Object of the testing: Determination of water vapour transmission properties according to. DIN EN ISO 12572:2001 ...
http://www.megapan.org/folders/X06110529.pdf
CEMproof®
SilverSeal „active“
DIN EN ISO 12572: 2001-09. SilverSeal specimen: 2,92 x 108 [kg/(m2 x h)]. 9,3 sd-value [m]. Document number: 5303/723/07 – Mc vom 18.04.2008 ...
http://www.pflieger.tv/Templates/SilverSeal Englisch08.pdf
Effects of
wear on static and dynamic failure loads of aluminium ...
DIN (1999) EN 12572: artificial climbing structures––protection points, stability requirements and test methods. European. Standard EN 12572 ...
http://www.springerlink.com/index/Y8R52N6N5N25V335.pdf
Fibers of
coffee husk and hulls for the production of particleboard
state method is the cup method (DIN EN ISO 12572). The measurements reported here have been per- formed in dry cup method at the Otto-Graf-Institute. ...
http://www.springerlink.com/index/7736401471252317.pdf
TÜV Zertifikat Paneelensystem
DIN EN 12572:1999-11 (Prüfung nach Anhang C). Gerätesicherheitsgesetz. Das vorgestellte Erzeugnis erfüllt die Anforderungen der o.g. ...
http://www.ontopklettern.de/images/pages/File/TUEV Zertifikat Paneelensystem ON TOP KLettern (deutsch).pdf
FERMACELL Powerpanel H O for Wet & Moisture affected areas
56 according to DIN EN 12572. Thermal conductivity 10,tr: 0.173 W/(mK) according to DIN EN 12664. Heat transfer resistance R 10,tr: ...
http://www.sheffins.co.uk/Literature/Fermacell H2O manual_S_0607.pdf
eximSilence – Impact Sound Insulation Mat 730F
DIN 52612. Steam diffusion resistance: µ = 15. DIN EN ISO 12572. Impact sound improvement. 21 db at 5 mm with 7 mm laminate flooring DIN EN ISO 140-8 ...
http://www.eximlink.com/wp-content/uploads/special_construction_products/eximsilence/eximSilence_Impact_Sound_Insulation_Mat_730F.pdf
Hannoband -F 600
Water vapour permeability. DIN EN ISO 12572. < 10 (when compressing to 20%). Thermal conductivity. DIN 12667 λ = 0.0429 W / mK, MPA*. Storage stability ...
http://www.hannoband.de/en/download/anschlussfugen/pdf/datenblaetter/dichtbaender/Hannoband_F600-TM_090818_englisch.pdf
Evidence of
Performance
properties as per DIN EN ISO 12572. Test Report 105 34243/3e. 07-12/745 ... Measurements carried out in accordance with DIN EN. ISO 12572 have revealed the ...
http://www.robitex.ru/files/ift_sert/pb.pdf
TECHNICAL
DATA SHEET
EN ISO 12572. Resistance to Water Pressure. No Leak (1m water column, 24h). DIN EN 1928. Adhesion to absorbent ceramic tile ...
http://www.marispolymers.gr/files/pdf/MARITRANS version5.pdf
pro clima
SOLITEX
DIN EN 12572. < 0,10 m. Wasserdichtheit. DIN EN 20811 wasserdicht ... DIN EN 12310-1. > 120 N sd-Wert. DIN EN 12572. < 0,05 m. Wasserdichtheit regendicht ...
http://www.naturbauhof.de/proclima/solitex_info.pdf
IN/IC CLAD SYSTEM
EN 12572 (BS 4370) EN ISO 12572. Closed cells. Corrosion DIN 1988/7*. Noise reduction. Noise absorption EN ISO 11654. Resistance to oils and fats ...
http://www.k-flex.ro/inic.pdf
ISO-CONNECT Vario SD
Compatibility with adjacent building materials DIN 52452 requirements fulfilled sd-value (vapour diffusion permeability). DIN EN ISO 12572 ...
http://www.iso-chemie.co.uk/material/product-data-sheets/iso-connect-vario-sd.pdf
ISO-BLOCO One Control
DIN EN ISO. 12572. 50 : 1 (internal > 25; external < 0,5). Shelf life. 1 year, dry and in original packing. Storage temperature. +1 °C to +20 °C ...
http://www.iso-chemie.co.uk/material/product-data-sheets/iso-bloco-one-control.pdf
TC 600/300
(DIN 53387). Compatibility with adjacent requirements fulfilled building materials (DIN 52453). Water vapour diffusion resistance. (DIN EN ISO 12572) ...
http://www.henkel321.com/fileadmin/pdf_040509/1/technical_datasheets/winteq/TDS_TC_600-300.pdf
Terofol dampfoffen
acc. to DIN EN ISO 12572. 3.7. Thermal stability at +90 °C: no visible changes. Brittle-point temperature at -30 °C: no cracks. UV stability: ...
http://www.henkel321.com/fileadmin/pdf_040509/1/technical_datasheets/winteq/TDS_TF_sd3.pdf
TECHNICAL
INFORMATION SHEET POLYMER SILICATE RESIN COATING
water penetration test following DIN EN 12390 and DIN EN 1766. • water vapour permeability according to DIN EN ISO 12572. Specifications ...
http://www.mh22systeme.com/pdf/technmerkblatt_en.pdf
(Microsoft Word - 4.Orientierungshilfe_Sportger\344te_Einbauger.u
...
DIN EN 913. (1996) Turngeräte; Allgemeine sicherheitstechnische Anforderungen und. Prüfverfahren. DIN EN 12572 (1999) Künstliche Kletteranlagen ...
http://www.sportministerkonferenz.de/dateien/4.Orientierungshilfe_Sportgeräte_Einbauger.u.transport.pdf
Hannoband -BG 1
DIN EN ISO 12572 sd < 0,5 m, 090666.1 MPA*. Caloric conductibility. DIN EN 12667 λ = 0,0429 W/mK, 083955.2, MPA*. Ecological expertise ...
http://www.hanno.com/en/download/anschlussfugen/pdf/datenblaetter/dichtbaender/Hannoband_BG_1-TM_090831_englisch.pdf
Hannoband -BG 2
DIN EN ISO 3386. 3,0 kPa (± 15 %), 40 % deformation. Water vapour diffusion. DIN EN ISO 12572 sd < 0,5 m, 092614.1 MPA*. Caloric conductibility. DIN 52 612 ...
http://www.hanno-werk.de/en/download/anschlussfugen/pdf/datenblaetter/dichtbaender/Hannoband_BG_2-TM_090921_englisch.pdf
PIPING AND EQUIPMENT INSULATION SPECIFICATION FOR LNGC SYSTEMS
...
EN 12086 (DIN 52615). µ > 7000. Water vapour permeability (23°C). EN 12572 (BS 4370) EN ISO 12572 δ = 1·10-10 kg/(m·Pa·hr). Density kg/m3 ...
http://www.kflexenergy.com/files/in_clad_specification_for_lng01.pdf
Jahresbericht 2001
DIN EN 12572-3. Eislaufkomplets - Sicherheitstechnische Anforderungen und Prüfverfahren. Rollsportgeräte - Skateboards - Sicherheitstechnische Anforderungen ...
http://www.nasport.din.de/sixcms_upload/media/2661/Aktuelles - Jahresbericht 2006 - Jahresbericht 2006 NASport.pdf
Permo
Light
Water Vapour Permeability EN ISO 12572 (g/m2/day). >1200. Weight (g/m2). 140. Tensile Strength DIN EN 12311-1. Longitudinal (N/5cm). 264. Transverse (N/5cm) ...
http://www.metseam.com/pdfs/klober/permo_light_lge.pdf
Permo
Forte
Water Vapour Permeability EN ISO 12572 (g/m2/day). >1200. Weight (g/m2). 187. Tensile Strength DIN EN 12311-1. Longitudinal (N/5cm). 491. Transverse (N/5cm) ...
http://www.metseam.com/pdfs/klober/permo_forte_lge.pdf
fegìster
DIN 4102-Teil 1, Bl. DIN 52612, 52613 and DIN EN ISO 12572. IMO-Resolution A. 653 (16). IMO-FTPC, Part 5. Mean temperature : -50°C to +85°C ...
http://www.armacell.com/www/armacell/ACwwwAttach.nsf/ansFiles/D2697.pdf/$File/D2697.pdf
ALUTRIX: Ultimate Performance
Water vapour resistance. BS EN ISO 12572. 4310 MNs/g. ■ Resistance to static loading method A & B. DIN EN 12730. A: 20 kg B: 20 kg. Typical application ...
http://www.pdt-waterproofing.com/pages/dokumentenarchiv/downloads/PDT_20090731_brochure_alutrix_600_en.pdf
EP 740 E_englisch.indd
TP OS 3.6 / DIN EN ISO3251 non-flammable kg/litre. DIN 51755. 1.32. DIN EN ISO 2811-2 (20°C). < 70 mg. ASTM D4060. 3100. -. DIN EN ISO 12572 ...
http://www.klbresins.ie/test33/wp-content/uploads/2009/06/klb_ep_740e_745.pdf
Readiris
DIN EN ISO 12572 Hygrotherma! performance of building materials and. 2001-09 products - Determination of water vapour transmission properties ...
http://www.tbu-gmbh.de/media_de_en/Akkreditierung_Anlage Urkunde DAP_e_2008.pdf
-Klettern
in der Schule
DIN EN 1176-1 Spielplatzgeräte. DIN EN 1177 Stoßdämpfende Spielplatzböden. DIN EN 12572 Künstliche Kletteranlagen. DIN 18 032-1 Sporthallen ...
http://www.flying-rock.de/images/Klettern in der Schule.pdf
WACKER POLYMERS - More Market Support. Burghausen Technical
Center
(EN 1324 and DIN 18156/3). – Determination of setting properties ... meability (EN 12572). – Determination of resistance to impact strength ...
http://www.wacker.com/cms/media/publications/downloads/6529_EN.pdf
030-0806 Klober
Sample Labels.qxp
Sd Value EN ISO 12572 (m). 0,02 m. Tensile strength, longitudinal 211 N/5 cm. DIN EN 12311-1 transverse 186 N/5 cm. Nail tear strength, longitudinal 171 N ...
http://www.hosekra.si/pdf/PermoEasyH.pdf
A
to Z of tiles
According to DIN EN ISO 12572, for vitreous (Blb) and porcelain stoneware tiles (Bla), the vapour diffusion resistance is approx, µ 120000 and, for ...
http://www.villeroy-boch.com/uploads/media/Fliesenlexikon_EN.pdf
LIST OF INTERNATIONAL STANDARDS FOR MEDICAL DEVICES NO STANDARD
...
ISO 12572 ; Pt 10. Guide for evaluation of medical devices for ... DIN EN 30993-6. Biological evaluation of medical devices- Test for local effects after ...
http://www.mdb.gov.my/mdb/documents/standards/international standard.pdf
2002 DIN
Catalogue of Technical Rules Volume 3 – Supplement ...
DIN. Date of issue. Title. EN ISO 12572. 09.01. Hygrothermal performance of building materials and products –. Determination of water vapour transmission ...
http://www.geass.com/pdf/DIN.pdf
• Underlay for warm and cold pitched roofs • Unventilated warm and
...
Water Vapour Resistance (Sd) (EN 12572). 0.037m. Resistance to Water Penetration (EN 1928). W1. Flame Retardancy. (EN 13501-1). Class D*. (DIN 4102-1) ...
http://www.lotrak.co.uk/products/industry/application/product/RollInserts/Roof TX A3 INSERT 903 26.6.081.pdf
441
IBP-Mitteilung
File Format: PDF/Adobe Acrobatby C FitzWährend die nach der alten DIN 52615 und glücklicherweise auch der DIN. EN ISO 12572 ermittelte Wasserdampfdiffusionswider- ...
http://www.ibp.fhg.de/literatur/ibpmitt/441.pdf
1 2