Hardware
Realisation Standard
EN 300 019-2-3. Class 3.1 Normal &. Exceptional. Conditions .... ETS 300 019 has been changed to EN 300 019 in Sections 3.1.1,. 3.1.2, Table 1 & References. ...
http://www.selling2bt.bt.com/Downloads/GS16_6.pdf
EN
300 019-1-3 - V2.3.2 -
Environmental Engineering (EE ...
random vibration are given in EN 300 019-2-3 [5] and these represent all types of .... Amendment 1 to 1st Edition of ETS 300 019-1-3. V2.1.1. March 2003 ...
http://www.eco-info.org/IMG/pdf/ETSI_en_3000190103v020302o.pdf
30 Watts RF Link Power
Supply
ETSI ETS 300 019-1-3 class 3.2 and ETS 300 019-2-3 test spec T 3.2. • Storage: ETSI ETS 300 019-1-1 class 1.2. • Transportation : ETSI ETS 300 019-2-3 class ...
http://www.agma.co.il/PSLINK30-3-5.pdf
ERM 48/60-300
EN 300386:2005 class B. ETS 300 132-1. ETS 300 132-2. Environmental. ETS 300 019-2-3 cl T3.2. ETS 300 019-2-1 cl T1.2. ETS 300 019-2-2 cl T2.3 ...
http://www.efore.com/products/dc_power/fi_FI/epos_mini_fi/_files/76851008405832256/default/ERM_48-60-300_RevA.pdf
Rectifier modules for EPOS Modular
ETS 300 019-2-3 cl T3.2. ETS 300 019-2-1 cl T1.2. ETS 300 019-2-2 cl T2.3. IEC 60068-2-6, test Fc. IEC 60068-2-27, test Ea. IEC 60068-2-64, test Fh ...
http://www.efore.com/products/dc_power/fi_FI/epos_modular_fi/_files/76308817878654998/default/ERM_RevA.pdf
XDM®-100 Miniature MSPP for Metro Access and Cellular Networks
Environmental standards. ETS 300 019-2-1 Class 1.2. ETS 300 019-2-2 Class 2.3. ETS 300 019-2-3 Class 3.1E/3.3 for STM-16. ETS 300 019-2-3 Class 3.2/3.3 ...
http://www.quante-netzwerke.de/Produkte/Transport/downloads/XDM-100_SDH-System_en.pdf
DNT2Mi
ETSI ETS 300019-2-2 class 2.3. Storage. ETSI ETS 300019-2-1 class 1.2. Operation. ETSI ETS 300019-2-3 class 3.2. Electromagnetic Compatibility ...
http://www.quante-netzwerke.de/Produkte/CPEs/downloads/DNT-2Mi_DSL_en.pdf
Panel
Antenna Test Specifications
Note 1: ETS 300 019-2-4 : 1994: (Stationary use on non-weatherprotected locations). European Telecommunication Standard. IEC 721-3-4 : 1995: (Stationary use ...
http://www.kathrein-scala.com/tech_bulletins/TestSpec.pdf
Product
Testing Equipment/Standards Product Test Product Testing ...
0.75 mm or in accordance with ETS. 300 019–1–4 class 4.1E conditions. Random Vibration Testing in accordance with ASTM D4169 Truck. Level 2 for 3 hours ...
http://awapps.commscope.com/misc/bsa/prodTestingEquipmnt.pdf
REQUIREMENTS FOR NETWORK TERMINATION CONNECTED TO U-INTERFACE OF
...
ETS 300 019-1-2 /ref. 20/ and ETS300 019-1-3 /ref. 21/. 4. MINIMUM REQUIREMENTS FOR NT+. 4.1 Minimum requirements for layer 1: U-Interface (NT-side) ...
http://www.ficora.fi/attachments/suomiry/1158858938467/TRaportti091997.pdf
MET LABORATORIES,
INC.
IEC 60068-2-6; IEC 60068-2-36; IEC 60721-3-4;. ETS 300-019-2-1 through 8. Salt Spray. GR-487;. RTCA/DO-160D & E, Sec 14.0;. MIL-STD-810 to Current, ...
http://www.a2la.org/scopepdf/0591-02.pdf
OrangeBox™
MSC
ETS 300 019-1-1, Class 1.1. Transportation. ETS 300 019-1-2, Class 2.3. ETS 300 019-1-2, Class 2.3. Operating conditions. ETS 300 019-2-3, Class 3.3 ...
http://www.vnl.in/productsheets/worldgsm_orangebox.pdf
BlueBox™
BTS
ETS 300 019-1-1, Class 1.1. Transportation. ETS 300 019-1-2, Class 2.3. ETS 300 019-1-2, Class 2.3. Operating conditions. ETS 300 019-1-4, Class 4.2H ...
http://www.vnl.in/productsheets/worldgsm_bluebox.pdf
DNT128 and
DNT128-sp
Transportation ETS 300019-1-2 class 2.3. Storage ETS 300019-1-1 class 1.2. Storage ETS 300019-1-1 class 1.2. Operation ETS 300019-1-3 class 3.2 ...
http://www.netcom-cz.cz/nokia/dnt128.pdf
Aethra
NT1 Plus Aethra
ETS 300 019-1-2 class 1.2. Storage. ETS 300 019-1-1 class 2.2. Operation. ETS 300 019-1-3 class 3.2. Overvoltages protection exceeds ITU-T K21. Mechanical ...
http://www.aethravideo.com/media/files/236_nt1plus_sc_18_2.pdf
AC-DC Converter REC2400-230-48-K5
ETS 300 019-1-3 class 3.3, extended to. +60°C ambient temperature during transport. ETS 300 019-1-2 class 2.3 during stocking. ETS 300 019-1-1 class 1.2 ...
http://www.powerinnovation.com/fileadmin/pdf_english/REC2400_230_48_K5_Eng.pdf
Alcatel 7570 MG
Part 2-2: Specification of environmental tests; Transportation. > ETS 300 019-2-3: Environmental conditions and environmental tests for telecommunications ...
http://rkpartner.ru/_photos/4/29.pdf
Exhibit A Communications Equipment on Vertical Mounting Assets
...
ETS 300 019 part 2-3 class 3.2E for indoor units. ETS 300 019 part 2-4 class 4.1E for outdoor units. Storage. ETS 300 019-2-1 class 1.2E. Transportation ...
http://www.sfgov.org/site/uploadedfiles/dtis/tech_connect/SFExhibitACommunicationsEquipment.pdf
FMP25.48 Rectifier Data Sheet
Operation: ETS 300 019-2-3. Earthquake: GR 63 Core Zone 4. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, ...
http://www.power-one.com/resources/power_plants/fmp2548.pdf
Ethernet Gateways EXN401 and EXN410
ETS 300 019-2-2 class 2.3 Transportation. • ETS 300 019-2-3 class 3.2 Operation. SAFETY. • UL 1950, IEC 60950, and EN 60950. POWER, GROUNDING AND BONDING ...
http://www.cpg.com.tr/File/EricssonDSLAM-EDA/27112007055730_Datasheet_EXN401_v.1D.pdf
287 01-EN/LZT 108 7069 Uen G: IP DSLAM EDN312x (EDA 2.0)
ETS 300 019-2-2 class 2.3, Transportation. • ETS 300 019-2-3 class 3.2, Operation. • Earthquake (Belcore GR-63-Core) zone 4. • ETS 300 019 2-4 class 4.1E ...
http://www.cpg.com.tr/File/EricssonDSLAM-EDA/27112007055424_Datasheet_EDN312x_v.1G.pdf
Tellabs
8600 Managed Edge System: 1-Port Channelized
STM-1/OC-3 ...
■Transportation: ETS 300 019-1-2:2003-04. Class 2.3, temperature: –40° C to 70° C. ■Normal operating conditions: ETS 300. 019-1-3:2003-04 Class 3.2 (non- ...
http://www.tellabs.com/products/8000/tlab8600-1xchstm-1msifm.pdf
STACCATO DVB TO
ATM PROCESSOR WITH ASI AND COMMON INTERFACES
ETS 300 019-1-1, Class 1.1. Transportation. ETS 300 019-1-2, Class 2.2. Operating. ETS 300 019-1-3, Class 3.2. EMC. EN 55022 Class B; EN 50082-1 ...
http://www.konturm.ru/catalogy/openg/STACCATO.pdf
alv_breezeNET
B_revi_Final
EN 61000-4-5, Class 3 (2kV). Environmental. Operation. ETS 300 019 part 2-3 class 3.2E for indoor unit. ETS 300 019 part 2-4 class 4.1E for outdoor unit ...
http://www.bauschdatacom.nl/productdata/B100_B_DatasheetA.pdf
BreezeACCESS® 900
Operation. ETS 300 019 part 2-3 class 3.2E for indoor units. ETS 300 019 part 2-4 class 4.1E for outdoor units. Storage. ETS 300 019-2-1 class 1.2E ...
http://www.scansourcesecurity.com/MicroSites/ScanSourceSecurity/quickstart/docs/BreezeACCESS900_distDS.pdf
Specifications
ETS 300 019 part 2-3 class 3.2E for indoor units. ETS 300 019 part 2-4 class 4.1E for outdoor units. Storage. ETS 300 019-2-1 class 1.2E. Transportation ...
http://wireless.ictp.it/school_2005/download/alvarion/BA_900_Datasheet.pdf
Proteus AMT
EN 300 132-2. Storage. ETS 300 019-1-1 (Class 1.1E). Transport. ETS 300 019-1-2 (Class 2.1E). Environmental - IDU. ETS 300 019-1-3 (Class 3.1E) ...
http://www.microwavenetworks.com/Datasheets/L-Series/L Series - ETSI - Rev0606.pdf
alv_BA900_ds
2
ETS 300 019 part 2-3 class 3.2E for indoor units. ETS 300 019 part 2-4 class 4.1E for outdoor units. Storage. ETS 300 019-2-1 class 1.2E. Transportation ...
http://www.sourcesecurity.com/docs/fullspec/BA_900_Datasheet.pdf
Nortel
WiMAX 1000 portfolio
Figure 4. EasyST. Figure 2. WiMAX BTS 1060. Figure 3. WiMAX BTS 1085. Figure 6. .... ETS 300 019-1-3 Class 3.2. RF. Specifications and features. BTS 1060 ...
http://www.nortel.com/solutions/wimax/collateral/nn115140.pdf
SV1021,
SV1042 & SV2042
Storage: ETSI EN 300 019-2-1 T 1.3. • Transportation: ETS 300 019-2-2, T 2.3. • Operating Conditions: ETS 300 019-2-3, T 3.2. • EMC: EN 55022, EN 55024, ...
http://www.aethra.com/media/files/779_ae_svx0xx_rev3_0109.pdf
ProServ 2700
Environmental and Compliance Tables
ETSI EN 300 386 — EMC requirements for Telecom Equip. • ETS 300-019-2-1 — Storage Tests, Class T1.2. • ETS 300-019-2-2 — Transportation Tests, Class T2.3 ...
http://www.servaris.com/pdf/proserv_2700_specs.pdf
Hardware Specifications
: CE EN 300 386:2003 Class B. ETS 300 019-2-1 class 1.2. ETS 300 019-2-2 class 2.3. ETS 300 019-2-3 class 3.2 ...
http://www.clavister.com/pdf/Clavister_Hardware_Specifications_9_0.pdf
Forderungen ETNO Energy Task Team
LO from 1,5 Watt today to 0,8 Watt in 2 years. 2. Extension of normal climatic limits change from ETS 300 019-1-3 Class 3.1 to Class 3.2 ...
http://re.jrc.ec.europa.eu/energyefficiency/pdf/Workshop_May.2005/Broadband comunication/Schiwy.pdf
ATCA-S110-600GB
Level 3, Equipment Type 2. Designed to comply with ETSI. ETSI Storage, ETS 300 019-2-1, Class 1.2 equipment, Not Temperature Controlled. Storage Locations ...
http://www.powerbridge.de/download/data/atca/ATCA-S110-600GB_DS_0801.pdf
Ethernet solution for MINI-LINK™ BAS
ETS 300 019-2-1 class 1.2 Storage. ETS 300 019-2-2 class 2.3 Transportation. ETS 300 019-2-3 class 3.2 Operation. Safety. UL 1950, IEC 60950, EN 60950 ...
http://sysdoc.doors.ch/SONYERICSSON/20D2A7BC-D2A2-4012-9DA3-DFF9769F732D_v1.pdf
BreezeACCESSо 4900
ETS 300 019 part 2-3 class 3.2E for indoor units. ETS 300 019 part 2-4 class 4.1E for outdoor units. Storage. ETS 300 019-2-1 class 1.2E. Transportation ...
http://www.netlinkweb.com/solutions/alvarion/BreezeAccess_4900_Datasheet.pdf
PPRD
16.64 Power System
ETS 300 019-2-2. ETS 300 019-2-3. GR 63 Core Zone 4. *Average performance for a single module. www.power-one.com. 11V0005-041 FMP 16 V3.0 Rev. B ...
http://www.uscpower.com/PowerOne - PPRD 16.48 DC System.pdf
Cisco ONS 15454 SONET 48-Port DS-3/EC-1 Interface
Card
Telcordia Technologies NEBS GR-63-CORE, Level 3. ETS 300 019-2-1 (Storage, Class 1.1). ETS 300 019-2-2 (Class 2.3). ETS 300 019-2-3 (Class 3.1E) ...
http://www.cisco.com/en/US/prod/collateral/optical/ps5724/ps2006/product_data_sheet0900aecd801b95d6.pdf
G21RRH-48-01B
Product Datasheet 4-Carrier WCDMA/HSDPA+/LTE CPRI ...
ETS 300 253 and TN-S IEC 364-3, 401-200-115. Storage. ETS 300 019-2-1 class 1.2. Transportation. ETS 300 019-2-2 class 2.3. Operational. ETS 300 019-2-4 ...
http://www.gpcs.com.tw/en/pdf/2.1ghz_60w_rrh.pdf
Cisco ONS 15454 60G/5G High-Order/Low-Order XC-VXC Cross-Connect
Card
NEBS Telcordia Technologies GR-63-CORE, Level 3. ETS 300 019-2-1 (Storage, Class 1.1). ETS 300 019-2-2 (Transportation, Class 2.3). ETS 300 019-2-3 ...
http://www.cisco.rw/en/US/prod/collateral/modules/ps2831/ps6343/product_data_sheet0900aecd8031a2d6.pdf
Datenblatt
9362940b, 78210313
ETS 300 342-3. Lightning protection. 5 kA, 8/20 μs pulse ... have passed environmental tests as recommended in ETS 300 019-2-4. ...
http://www.kathrein.de/de/mcs/produkte/download/9362940b.pdf
CXA10 (Page
1)
Complies with ETS 300 019-1-3/2-3. • Complies with ETS 300 132-2 input voltage and current requirements. • Fully compliant with ETS 300 386-1 ...
http://ysjcpower.com/products/picture/CXA10.pdf
Motorola's low-noise, high-power, multiple output, Erbium-Doped
...
EN 60825-2. 21 CFR 1040. EMC. FCC Part 15 (CFR 47) Class A. ICES-003 Class A ... GR-1089-Core NEBS Level 3 Requirements. ETS 300 019 Storage Class 1.1 ...
http://www.motorola.com/staticfiles/Business/Products/Cable Broadband/Optical Amplifiers/N2U-OA200/_Documents/Static Files/N2U-OA200 (doc513564-001).pdf?localeId=33
IP DSLAM
EDN312x
ETS 300 019-2-2 class 2.3, Transportation. ETS 300 019-2-3 class 3.2, Operation. Earthquake (Belcore GR-63-Core) zone 4. ETS 300 019 2-4 class 4.1E (outdoor ...
http://www.btg-gruppe.de/IP_DSLAM_EDN312x_Rev_G.pdf
TrueNet®
ETS 300-019-2-3 Class 3.2. Storage:..................................................................................................... ETS 300-019-2-1 ...
http://www.adckrone.com.au/au/en/library/specsheets/Carrier/ADX-7072_2_01X-00&-01.pdf
Microsoft PowerPoint - IEEE.jul01
ETS 300 019-1-4 class 4.1E. NOTE1 – Option 1: short term refers to a period of .... 60793-2 regarding the B1.3 fibre category (see also Appendix V [B.2]). ...
http://www.ieee802.org/3/efm/public/jul01/presentations/carlisle_1_0701.pdf
DNT2Mi-fp Network Terminal
ETSI ETS 300 019-2-2 class 2.3. Storage. ETSI ETS 300 019-2-1 class 1.2. Operation. ETSI ETS 300 019-2-3 class 3.2. Electromagnetic Compatibility ...
http://commtelnetworks.com/pdf/brochures/Broadband/01-4DNT2MI-fpG7034_V2.pdf
Layout 1
Compliant with ETS 300 019-1-3 May 1992 + ammendment 1 June 1997 class 3.1. 2. Compliant with ETS 300 019-1-1 Feb 1992 class 1.1, ETS 300 019-1-2 Feb 1992 ...
http://www.xppower.com/pdfs/SF_DMA.pdf
DNT2Mi brochure
ETSI ETS 300 019-2-2 class 2.3. Storage. ETSI ETS 300 019-2-1 class 1.2. Operation. ETSI ETS 300 019-2-3 class 3.2. Electromagnetic Compatibility ...
http://telekomservisas.lt.narcizas.serveriai.lt/EasyAdmin/sys/files/DNT2Mi.pdf
PERSEUS
Wireless Remote Dispatcher RDS - Radio Dispatcher Station
Compliant ETS 300 019-1-3 Class 3.1E. ETSI ETS 300 019-1-3 class 3.1. ETSI ETS 300 019-1-1 class 1.2. ETSI ETS 300 019 1-2 class 2.2. EN 550022 Class A. ...
http://94.127.81.83/internet/media/docs/PERSEUS_RDS_EN_LR.pdf
1 2