LTTA
Data Journal no date
RTI mainly involves the thermal aging and testing of ... Some examples of UL methods: UL 94. UL 746B. Relative. Thermal. Indexing ...
http://www.elteklabs.com/includes/LTTA_Data_Journal_no_date.pdf
Formex GK/Formex Product Flame
Retardant Polypropylene
TEST METHOD. FORMEX-10. FORMEX GK-10. FORMEX GK-17. FORMEX GK-30. FORMEX GK-40 .... 121˚C/250˚F. 106˚C/223˚F. 106˚C/223˚F. RELATIVE THERMAL INDEX. UL 746B ...
http://www.orionind.com/formex.pdf
ZYTEL
70G30HSLR BK099
RTI, Electrical. UL 746B. °C. 0.75mm. 140. RTI, Impact. UL 746B ... the basis of design; they are not intended to substitute for any testing you may need to ...
http://cgtec.eu/wp-content/uploads/ZYTEL70G30HSLRBK0.pdf
CRASTIN
S620F20 BK851
RTI, Electrical. UL 746B. °C. 0.75mm. 130. RTI, Impact. UL 746B ... the basis of design; they are not intended to substitute for any testing you may need to ...
http://cgtec.eu/wp-content/uploads/CRASTINS620F20BK851.pdf
ZYTEL 70G33L BK031
Zytel® 70G33L BK031. Property. Test Method. Units. Value. DAM. Thermal. CLTE, Normal. ASTM E 831 ... Temperature Index. RTI, Electrical. UL 746B ...
http://www.classic-coil.com/classic-coil/literature/Zytel 70G33LBK1.pdf
RYNITE FR530 NC010
Test Method. Units. Value. Mechanical. Tensile Strength. ASTM D 638. MPa (kpsi) .... UL 746B. °C. 0.81mm. 150. RTI, Mechanical with Impact. UL 746B ...
http://www.classic-coil.com/classic-coil/literature/RYNITE FR530NC.pdf
RYNITE FR945 BK507
polyethylene terephthalate resin for injection molding. Recognized by UL as UL94V-0 at 0.81mm and with a. 150°C RTI. Property. Test Method ...
http://plastics.dupont.com/plastics/dsheets/rynite/RYNITEFR945BK507.pdf
CRASTIN SK603 BK851
Crastin® SK603 BK851. Temperature Index. RTI, Electrical. UL 746B ... they are not intended to substitute for any testing you may need to ...
http://plastics.dupont.com/plastics/dsheets/crastin/CRASTINSK603BK851.pdf
Norton® Polyimide Film
Test. Condition. Test Method. Mechanical Tensile. Strength lbs/inch2 ... Electrical RTI ºF. 455. 455. 455. 455. 455. 455. –. UL 746B. Mechanical. RTI ...
http://www.oilandgas.saint-gobain.com/uploadedFiles/SGoilandgas/Documents/Films/PIFilm-THSeries-AFF1467.pdf
RYNITE 520
NC010
Test Method. Units. Value. Temperature Index. RTI, Electrical. UL 746B. °C. 0.75mm. 140. RTI, Mechanical with Impact. UL 746B ...
http://www.zmplas.com/uploadfile/20070710193209966.pdf
ZYTEL
71G33L NC010
Test Method. Units. Value. DAM. 50%RH. Temperature Index. RTI, Mechanical with Impact. UL 746B. °C. 0.71mm. 65. 1.5mm. 65. 3.0mm. 65. RTI, Mechanical ...
http://www.zmplas.com/uploadfile/20070711104928847.pdf
Makrolon 6265 Makrolon
C Oxygen index. Method A. %. ISO 4589-2. 36. Thermal conductivity ... UL 746 B. 125. Relative temperature index (Tensile impact strength) ... Needle flame test. Method K; 1.5 mm s. IEC 60695-2-2. 60. Needle flame test. Method K; 2.0 mm ...
http://www.dghuixin.com.cn/product/image/Makrolon_6265_ISO_internet.pdf
Makrolon 2658 Makrolon
C Oxygen index. Method A. %. ISO 4589-2. 27. Thermal conductivity ... UL 746 B. 125. Relative temperature index (Tensile impact strength) ... Needle flame test. Method K; 1.5 mm s. IEC 60695-2-2. 5. Needle flame test. Method K; 2.0 mm ...
http://www.dghuixin.com.cn/product/image/Makrolon_2658_ISO_internet.pdf
DELRIN 527UV
BK701
Test temperatures are 23°C unless otherwise stated. ... Temperature Index. RTI, Electrical. UL 746B. °C. 0.84mm. 50. RTI, Impact. UL 746B ...
http://www.cpinfo.net/scissc/Delrin/527UV.pdf
ZYTEL FR50
NC010
Test temperatures are 23°C unless otherwise stated. The DuPont Oval Logo, .... UL 746B. °C. 0.75mm. 130. 1.5mm. 130. 3.0mm. 130. RTI, Impact. UL 746B ...
http://www.cpinfo.net/scissc/Zytel/FR50.pdf
Makrolon 9415 Makrolon
C Oxygen index. Method A. %. ISO 4589-2. 35. Thermal conductivity ... UL 746B. 125. Relative temperature index (Tensile impact strength) [UL recognition] ... Needle flame test. Method K; 1.5 mm s. IEC 60695-11-5. 60. Needle flame test ...
http://plastics.bayer.com/plastics/emea/en/product/makrolon/product_datasheets/Makrolon_9415_ISO/docId-66077/Makrolon_9415_ISO.pdf
Makrolon 2405 Makrolon
C Oxygen index. Method A. %. ISO 4589-2. 27. Thermal conductivity ... UL 746B. 125. Relative temperature index (Tensile impact strength) [UL recognition] ... Needle flame test. Method K; 1.5 mm s. IEC 60695-11-5. 5. Needle flame test ...
http://plastics.bayer.com/plastics/emea/en/product/makrolon/product_datasheets/Makrolon_2405_ISO/docId-77994/Makrolon_2405_ISO.pdf
A Brief
Description of High Performance Thermoplastics (HPTP ...
Evaluations, UL 746B . RTI is considered as the maximum useful service ... of property-specific performance testing relative to plastic material RTI: ...
http://www.chinaarray.com/ThermoplasticsAppendix.pdf
IEEE Standard for the Preparation of Test
Procedures for the ...
The relative temperature index (RTI) is derived at an arbitrary time by comparing the ..... One scheme which has been used, ANSI/UL 746B-1974 [5] uses the ...
http://ieeexplore.ieee.org/iel5/9546/30237/01389198.pdf?arnumber=1389198
IEEE
Standard For The Preparation Of Test Procedures
For The ...
(RTI). The relative temperature index (RTI) is derived ...... materials. One scheme which has been used,. ANSI/UL. 746B-1974 [5] uses the following ...
http://ieeexplore.ieee.org/iel1/4411/12545/00578053.pdf
Makrolon
2407 Makrolon
C Oxygen index. Method A. %. ISO 4589-2. 27. Thermal conductivity ... UL 746B. 125. Relative temperature index (Tensile impact strength) [UL recognition] ... Needle flame test. Method K; 1.5 mm s. IEC 60695-2-2. 5. Needle flame test ...
http://www.teko.it/multimedia/manuali/materiali/2407.pdf
ZYTEL
70G13L NC010
Test Method. Units. Value. DAM. 50%RH. Temperature Index. RTI, Electrical. UL 746B. °C. 0.71mm. 105. 1.5mm. 120. 3.0mm. 120. RTI, Mechanical with Impact ...
http://nylon-plastic-resin.com/data sheets/y70g13l.pdf
formex_excerpt.indd
TEST METHOD FORMEX GK-5BK FORMEX GK-10 FORMEX GK-17 FORMEX GK-30 ... Relative Thermal Index. UL 746B. Electrical. 115°C/239°F. 115°C/239°F. 115°C/239°F ...
http://www.itwformex.com/pdf/formex_gatefold.pdf
Makrolon 2805 Makrolon
C Oxygen index. Method A. %. ISO 4589-2. 27. Thermal conductivity ... UL 746 B. 125. Relative temperature index (Tensile impact strength) ... Needle flame test. Method K; 1.5 mm s. IEC 60695-2-2. 5. Needle flame test. Method K; 2.0 mm ...
http://www.de-fa.com.cn/product/image/Makrolon_2805_ISO_internet.pdf
Makrolon
3103 Makrolon
C Oxygen index. Method A. %. ISO 4589-2. 27. Thermal conductivity ... UL 746 B. 125. Relative temperature index (Tensile impact strength) .... Test values. Unless specified to the contrary, the values given have been established on ...
http://de-fa.com.cn/product/image/Makrolon_3103_ISO_internet.pdf
Makrolon
9125 Makrolon
C Oxygen index. Method A. %. ISO 4589-2. 36. Thermal conductivity ... UL 746B. 125. Relative temperature index (Tensile impact strength) [UL recognition] ... Needle flame test. Method K; 2.0 mm s. IEC 60695-2-2. 120. Makrolon 9125 ...
http://www.midasrl.info/pdf/Makrolon_9125_ISO_internet.pdf
Makrolon
DP1-1857 Makrolon
C Oxygen index. Method A. %. ISO 4589-2. 27. Thermal conductivity ... UL 746B. 80. Relative temperature index (Tensile impact strength) [UL recognition] ... Needle flame test. Method K; 1.5 mm s. IEC 60695-2-2. 5. Needle flame test ...
http://www.midasrl.info/pdf/Makrolon_DP1-1857_ISO_internet.pdf
FORMEX™
GK/FORMEX PRODUCT DATA FORMEX™ GK/FORMEX PRODUCT DATA
TEST METHOD. FORMEX GK-5BK. FORMEX GK-10. FORMEX GK-17. FORMEX GK-30 ... Relative Thermal Index. UL 746B. Electrical. 115°C/239°F. 115°C/239°F. 115°C/239°F ...
http://www.hstmaterials.com/images/Formex.pdf
DELRIN
500CL NC010
Test temperatures are 23°C unless otherwise stated. The DuPont Oval Logo, DuPont™, .... Delrin® 500CL NC010. Temperature Index. RTI, Impact. UL 746B ...
http://www.totalplastics.com/assets/DELRIN500CLNC010.pdf
ZYTEL 70G33L NC010
Test temperatures are 23°C unless otherwise stated. The DuPont Oval Logo, DuPont™, .... RTI, Electrical. UL 746B. °C. 0.71mm. 130. RTI, Impact. UL 746B ...
http://www.valueplastics.com/technical/material/Nylon/Dupont ZYTEL70G33L Material Data.pdf
DELRIN 500P NC010
Test temperatures are 23°C unless otherwise stated. The DuPont Oval Logo, .... UL 746B. °C. 0.75mm. 50. 1.5mm. 85. 3.0mm. 90. RTI, Strength. UL 746B ...
http://www.valueplastics.com/technical/material/Acetal/Dupont Delrin 500P Material Data.pdf
ZENITE 6140L BK & WT
Test Method. Units. Value. Temperature Index. RTI, Electrical. UL 746B. °C. Black, 0.8mm. 240. Black, 1.5mm. 240. Black, 3.0mm. 240. RTI, Mechanical with ...
http://www.gddatian.com/img/086.pdf
ZYTEL 70G43L BK031
Test Method. Units. Value. DAM. Mechanical. Tensile Strength. ASTM D 638. MPa (kpsi). 207 (30.0) ... Temperature Index. RTI, Electrical. UL 746B ...
http://www.gddatian.com/img/0116.pdf
ZYTEL 101L
NC010
Test temperatures are 23°C unless otherwise stated. The DuPont Oval Logo, DuPont™, .... RTI, Electrical. UL 746B. °C. 0.71mm. 130. RTI, Impact. UL 746B ...
http://www.vistatek.com/pdfs/ZYTEL101LNC010.pdf
DELRIN 100P
NC010
Test temperatures are 23°C unless otherwise stated. The DuPont Oval Logo, .... UL 746B. °C. 0.75mm. 50. 1.5mm. 110. 3.0mm. 110. RTI, Impact. UL 746B ...
http://www.vistatek.com/pdfs/DELRIN100PNC010.pdf
HYTREL
6358
ISO 34-1 method B/a. kN/m (lb/in). Normal. 145 (829). Parallel ... Test specimen for ISO 527 is 1BA (2mm) at 50mm/min; all other ISO & ASTM mechanical properties ... UL 746A s. 3.0mm. 31. Temperature Index. RTI, Electrical. UL 746B ...
http://www.salvagesettlers.com/auctions/IA69/HYTREL 6358.pdf
HT50 Product
Info
Mechanical Impact RTI. UL 746B. °C. 50. Mechanical Strength RTI. UL 746B ... ii) All values of UL testing methods refer to minimum thickness of 1.5mm. ...
http://www.idemitsu-ps.com.my/HT50 Product Info.pdf
ZYTEL® 70G33L
BK031
Zytel® 70G33L BK031. Property. Test Method. Units. Value. DAM. Thermal. CLTE, Flow. ASTM E 831 ... Temperature Index. RTI, Electrical. UL 746B ...
http://www.durgaelectronics.com/material/n66.pdf
The Gund
Company Introduces PolyPro FR Flame Retardant Polypropylene
Relative Thermal Index. UL 746B. Electrical. 213oF / 100oC. 213oF / 100oC ... Test Method PolyPro FR - .040”. PolyPro FR - .062”. Polypro FR - .094” ...
http://www.polyprofr.com/Material Data/PolyPro FR.pdf
Meeting
Log - UL Requirements for Polymeric (Plastic)
Materials ...
Charpy, and Flex Test Methods; therefore, UL considers it appropriate to ...... Any published "Yellow Card" UL 746A indexing or UL 746B RTI ratings are ...
http://www.cpsc.gov/LIBRARY/FOIA/meetings/mtg96/polymeric.pdf
Meeting Log - Attenance Of UL 746/UL94 Industry
Advisory Group ...
CONSIDERATION OF RAPID RTI METHODOLOGIES - UL 746B. DISCUSSION ... comparison of the present UL 746C test method versus the new Fixed Time Frame Method ...
http://www.cpsc.gov/library/foia/meetings/mtg99/industrypart1.pdf
DuPont
Tedlar* PVF Film Offerings for Photovoltaic Module Backsheets
UL 746B RTI, Electrical, °C. 140. UL 746B RTI, Mechanical (Impact Str), °C 120, 125 .... TEST METHOD. PV2000. PV2100. Identification. Complete. Complete ...
http://www.ea-nrw.de/pv/workshop2007/5Roekens_PVF.pdf
Durethan A 30 S 000000
UL 746B. 65. Relative temperature index, mechanical with impact. Thickness tested: 1.5 mm °C ... Therefore, it is imperative that you test our products, ...
http://techcenter.lanxess.com/scp/americas/en/products/datasheet/Durethan_A_30_S_000000_ASTM_internet.pdf?docId=187762
Pocan B 4225 000000
C Oxygen index. Method A. %. ISO 4589-2. 32. Thermal conductivity ... Relative temperature index (Tensile impact strength). °C. UL 746B ... Therefore, it is imperative that you test our products, technical assistance and information to ...
http://techcenter.lanxess.com/scp/americas/en/products/datasheet/Pocan_B_4225_000000_ISO_internet.pdf?docId=172741
Improved
Weathering Performance In Flame Resistant Pc/Abs Blends ...
by S Siripurapu - Related articles
http://kbam.geampod.com/KBAM/Reflection/Assets/19486.pdf
RYNITE 530
BK503
UL 746B. °C. 140. RTI, Mechanical with Impact. UL 746B ... alone as the basis of design; they are not intended to substitute for any testing you may need to ...
http://sheng-yu.cn/upload/200991491539.pdf
ZYTEL 70G30HSL
NC010
Test temperatures are 23°C unless otherwise stated. The DuPont Oval Logo, .... UL 746B. °C. 0.75mm. 140. 1.5mm. 140. 3.0mm. 140. RTI, Impact. UL 746B ...
http://sheng-yu.cn/upload/200999160127.pdf
Crastin® PBT
RTI, Mechanical without Impact. UL 746B. °C. 3.0mm. 140. Thermal ... they are not intended to substitute for any testing you may need to ...
http://shtnc.com/UploadImgs/200581713155722.pdf
HYTREL 5556
Test temperatures are 23°C unless otherwise stated. Specimum used for method ISO 527-1/-2 is ISO 1BA .... UL 746B. °C. 1.47mm. 85. 3.0mm. 85. RTI, Mechanical without Impact .... processing by all standard thermoplastic methods. ...
http://shtnc.com/UploadImgs/2005817132719350.pdf
MINLON 22C BK086
Test temperatures are 23°C unless otherwise stated. ... Temperature Index. RTI, Electrical. UL 746B. °C. 0.81mm. 65. RTI, Impact. UL 746B ...
http://www.luxinsj.com/adminmanage/ewebeditor/uploadfile/20091103103808297.pdf